Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Immediate Hypersensitivity Reaction to Gadolinium-based MR Contrast Media

Jung, Jae-Woo, Kang, Hye-Ryun, Kim, Min-Hye, Lee, Whal, Min, Kyung-Up, Han, Moon-Hee, Cho, Sang-Heon · 2012 · Radiology

Abstract

PURPOSE: To determine the incidence and risk factors of immediate hypersensitivity reactions to gadolinium-based magnetic resonance (MR) contrast agents. MATERIALS AND METHODS: Institutional review board approval and a waiver of informed consent were obtained. A retrospective study of patients who had been given gadolinium-based MR contrast media between August 2004 and July 2010 was performed by reviewing their electronic medical records. In addition to data on immediate hypersensitivity reaction, the kinds of MR contrast media and demographic data including age, sex, and comorbidity were collected. To compare the groups, the χ(2) test, Fisher exact test, χ(2) test for trend, Student t test, analysis of variance test, and multiple logistic regression test were performed. RESULTS: A total of 112 immediate hypersensitivity reactions (0.079% of 141 623 total doses) were identified in 102 patients (0.121% of 84 367 total patients). Among the six evaluated MR contrast media, gadodiamide had the lowest rate (0.013%) of immediate hypersensitivity reactions, while gadobenate dimeglumine had the highest rate (0.22%). The rate for immediate hypersensitivity reactions was significantly higher in female patients (odds ratio = 1.687; 95% confidence interval: 1.143, 2.491) and in patients with allergies and asthma (odds ratio = 2.829; 95% confidence interval: 1.427, 5.610). Patients with a previous history of immediate hypersensitivity reactions had a higher rate of recurrence after reexposure to MR contrast media (30%) compared with the incidence rate in total patients (P < .0001). The incidence of immediate hypersensitivity reactions increased depending on the number of times patients were exposed to MR contrast media (P for trend = .036). The most common symptom was urticaria (91.1%), and anaphylaxis occurred in 11 cases (9.8%). The mortality rate was 0.0007% because of one fatality. CONCLUSION: The incidence of immediate hypersensitivity reactions to MR contrast media was 0.079%, and the recurrence rate of hypersensitivity reactions was 30% in patients with previous reactions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12112025

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 244

Metadata

Authors
Jung, J.-W., Kang, H.-R., Kim, M.-H., Lee, W., Min, K.-U., Han, M.-H., & Cho, S.-H.
Venue
Radiology
Published
2012-08
Volume
264
Issue
2
Pages
414-422
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2120297079
Cited by
244
References
2
FWCI
8.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Immediate Hypersensitivity Reaction to Gadolinium-based MR Contrast Media. https://app.cochat.ai/papers/10.1148/radiol.12112025
The paper
Jung, J.-W., Kang, H.-R., Kim, M.-H., Lee, W., Min, K.-U., Han, M.-H., & Cho, S.-H. (2012). Immediate Hypersensitivity Reaction to Gadolinium-based MR Contrast Media. Radiology. https://doi.org/10.1148/radiol.12112025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.