CoChat

Computer-aided Detection of Masses at Mammography: Interactive Decision Support versus Prompts

Hupse, Rianne, Samulski, Maurice, Lobbes, Marc B., Mann, Ritse M., Mus, Roel, den Heeten, Gerard J., Beijerinck, David, Pijnappel, Ruud M., Boetes, Carla, Karssemeijer, Nico · 2013 · Radiology
Cited by 60

The DOI matches its Crossref record.

Abstract

PURPOSE: To compare effectiveness of an interactive computer-aided detection (CAD) system, in which CAD marks and their associated suspiciousness scores remain hidden unless their location is queried by the reader, with the effect of traditional CAD prompts used in current clinical practice for the detection of malignant masses on full-field digital mammograms. MATERIALS AND METHODS: The requirement for institutional review board approval was waived for this retrospective observer study. Nine certified screening radiologists and three residents who were trained in breast imaging read 200 studies (63 studies containing at least one screen-detected mass, 17 false-negative studies, 20 false-positive studies, and 100 normal studies) twice, once with CAD prompts and once with interactive CAD. Localized findings were reported and scored by the readers. In the prompted mode, findings were recorded before and after activation of CAD. The partial area under the location receiver operating characteristic (ROC) curve for an interval of low false-positive fractions typical for screening, from 0 to 0.2, was computed for each reader and each mode. Differences in reader performance were analyzed by using software. RESULTS: The average partial area under the location ROC curve with unaided reading was 0.57, and it increased to 0.62 with interactive CAD, while it remained unaffected by prompts. The difference in reader performance for unaided reading versus interactive CAD was statistically significant (P = .009). CONCLUSION: When used as decision support, interactive use of CAD for malignant masses on mammograms may be more effective than the current use of CAD, which is aimed at the prevention of perceptual oversights.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12120218

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hupse, R., Samulski, M., Lobbes, M. B., Mann, R. M., Mus, R., den Heeten, G. J., Beijerinck, D., Pijnappel, R. M., Boetes, C., & Karssemeijer, N.
Venue
Radiology
Published
2013-01
Volume
266
Issue
1
Pages
123-129
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2130635849
Cited by
60
References
0
FWCI
2.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.