CoChat

Quantification of Muscle Fat in Patients with Low Back Pain: Comparison of Multi-Echo MR Imaging with Single-Voxel MR Spectroscopy

Fischer, Michael A., Nanz, Daniel, Shimakawa, Ann, Schirmer, Timo, Guggenberger, Roman, Chhabra, Avneesh, Carrino, John A., Andreisek, Gustav · 2013 · Radiology
Cited by 155

The DOI matches its Crossref record.

Abstract

PURPOSE: To compare lumbar muscle fat-signal fractions derived from three-dimensional dual gradient-echo magnetic resonance (MR) imaging and multiple gradient-echo MR imaging with fractions from single-voxel MR spectroscopy in patients with low back pain. MATERIALS AND METHODS: This prospective study had institutional review board approval, and written informed consent was obtained from all study participants. Fifty-six patients (32 women; mean age, 52 years ± 15 [standard deviation]; age range, 20-79 years) with low back pain underwent standard 1.5-T MR imaging, which was supplemented by dual-echo MR imaging, multi-echo MR imaging, and MR spectroscopy to quantify fatty degeneration of bilateral lumbar multifidus muscles in a region of interest at the intervertebral level of L4 through L5. Fat-signal fractions were determined from signal intensities on fat- and water-only images from both imaging data sets (dual-echo and multi-echo fat-signal fractions without T2* correction) or directly obtained, with additional T2* correction, from multi-echo MR imaging. The results were compared with MR spectroscopic fractions. The Student t test and Bland-Altman plots were used to quantify agreement between fat-signal fractions derived from imaging and from spectroscopy. RESULTS: In total, 102 spectroscopic measurements were obtained bilaterally (46 of 56) or unilaterally (10 of 56). Mean spectroscopic fat-signal fraction was 19.6 ± 11.4 (range, 5.4-63.5). Correlation between spectroscopic and all imaging-based fat-signal fractions was statistically significant (R(2) = 0.87-0.92; all P < .001). Mean dual-echo fat-signal fractions not corrected for T2* and multi-echo fat-signal fractions corrected for T2* significantly differed from spectroscopic fractions (both P < .01), but mean multi-echo fractions not corrected for T2* did not (P = .11). There was a small measurement bias of 0.5% (95% limits of agreement: -6.0%, 7.2%) compared with spectroscopic fractions. CONCLUSION: Large-volume image-based (dual-echo and multi-echo MR imaging) and spectroscopic fat-signal fractions agree well, thus allowing fast and accurate quantification of muscle fat content in patients with low back pain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12120399

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 155

Metadata

Authors
Fischer, M. A., Nanz, D., Shimakawa, A., Schirmer, T., Guggenberger, R., Chhabra, A., Carrino, J. A., & Andreisek, G.
Venue
Radiology
Published
2013-02
Volume
266
Issue
2
Pages
555-563
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2025024762
Cited by
155
References
0
FWCI
5.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of Muscle Fat in Patients with Low Back Pain: Comparison of Multi-Echo MR Imaging with Single-Voxel MR Spectroscopy. https://app.cochat.ai/papers/10.1148/radiol.12120399
The paper
Fischer, M. A., Nanz, D., Shimakawa, A., Schirmer, T., Guggenberger, R., Chhabra, A., Carrino, J. A., & Andreisek, G. (2013). Quantification of Muscle Fat in Patients with Low Back Pain: Comparison of Multi-Echo MR Imaging with Single-Voxel MR Spectroscopy. Radiology. https://doi.org/10.1148/radiol.12120399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.