The DOI matches its Crossref record.
Adnexal Masses: Development and Preliminary Validation of an MR Imaging Scoring System
Abstract
PURPOSE: To construct and undertake preliminary validation of a magnetic resonance (MR) imaging scoring system designed for use in pelvic MR imaging performed for characterization of adnexal masses that were indeterminate at ultrasonography (US). MATERIALS AND METHODS: The institutional ethics committee approved this retrospective study and granted a waiver of informed consent. The study population comprised 394 women who underwent MR imaging between January 1, 2008, and October 30, 2010, for characterization of 497 adnexal masses that were seen at US. Then, masses were chronologically divided into a training set (329 masses) and a validating set (168 masses). Two radiologists who were blinded to the clinical findings retrospectively evaluated MR imaging criteria for characterization of adnexal masses. In the training set, the positive likelihood ratio (PLR) of malignancy and κ values were calculated for each criterion. The reference standard was surgical pathologic findings or findings at imaging follow-up of at least 1 year. On the basis of the PLR and multivariate analysis, a five-category MR scoring system called the ADNEX MR SCORING system was created and was subsequently tested by six readers with the validating set. RESULTS: There was almost perfect agreement (κ > 0.80) for each MR imaging feature except for grouped septa (κ = 0.558) and thickened regular septa (κ = 0.555). The classification was accurate in both the training set (area under the receiver operating characteristic [ROC] curve [AUC] = 0.981 for reader 1 and 0.961 for reader 2) and the validating set (AUC = 0.964 for reader 1 and 0.943 for reader 2). ROC curve analysis demonstrated that the optimal cutoff point was an ADNEX MR score of 3; an ADNEX MR score of 4 or higher was associated with malignancy with a sensitivity of 93.5% (58 of 62) and a specificity of 96.6% (258 of 267). CONCLUSION: In this study, a reproducible and accurate MR imaging scoring system that has the potential to improve patient care was developed and tested. Multicenter prospective validation of the score is warranted. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13121161/-/DC1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Andreotti, R. F., Timmerman, D., Strachowski, L. M., Froyman, W., Benacerraf, B. R., Bennett, G. L., Bourne, T., Brown, D. L., Coleman, B. G., Frates, M. C., et al. (2020) · Radiology · doi:10.1148/radiol.2019191150 · Cited by 506
Thomassin-Naggara, I., Poncelet, E., Jalaguier-Coudray, A., Guerra, A., Fournier, L. S., Stojanovic, S., Millet, I., Bharwani, N., Juhan, V., Cunha, T. M., et al. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.19896 · Cited by 296
Self-citationESUR recommendations for MR imaging of the sonographically indeterminate adnexal mass: An update
Forstner, R., Thomassin-Naggara, I., Cunha, T. M., Kinkel, K., Masselli, G., Kubik-Huch, R., Spencer, J. A., & Rockall, A. (2017) · European Radiology · doi:10.1007/s00330-016-4600-3 · Cited by 204
Self-citation
Metadata
- Authors
- Thomassin-Naggara, I., Aubert, E., Rockall, A., Jalaguier-Coudray, A., Rouzier, R., Daraï, E., & Bazot, M.
- Venue
- Radiology
- Published
- 2013-05
- Volume
- 267
- Issue
- 2
- Pages
- 432-443
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2120724145
- Cited by
- 223
- References
- 0
- FWCI
- 12.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adnexal Masses: Development and Preliminary Validation of an MR Imaging Scoring System. https://app.cochat.ai/papers/10.1148/radiol.13121161
- The paper
- Thomassin-Naggara, I., Aubert, E., Rockall, A., Jalaguier-Coudray, A., Rouzier, R., Daraï, E., & Bazot, M. (2013). Adnexal Masses: Development and Preliminary Validation of an MR Imaging Scoring System. Radiology. https://doi.org/10.1148/radiol.13121161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.