The DOI matches its Crossref record.
Prostate Cancer Localization Using Multiparametric MR Imaging: Comparison of Prostate Imaging Reporting and Data System (PI-RADS) and Likert Scales
Abstract
PURPOSE: To compare the recently proposed Prostate Imaging Reporting and Data System (PI-RADS) scale that incorporates fixed criteria and a standard Likert scale based on overall impression in prostate cancer localization using multiparametric magnetic resonance (MR) imaging. MATERIALS AND METHODS: This retrospective study was HIPAA compliant and institutional review board approved. Seventy patients who underwent 3-T pelvic MR imaging, including T2-weighted imaging, diffusion-weighted imaging, and dynamic contrast material-enhanced imaging, with a pelvic phased-array coil before radical prostatectomy were included. Three radiologists, each with 6 years of experience, independently scored 18 regions (12 peripheral zone [PZ], six transition zone [TZ]) using PI-RADS (range, scores 3-15) and Likert (range, scores 1-5) scales. Logistic regression for correlated data was used to compare scales for detection of tumors larger than 3 mm in maximal diameter at prostatectomy. RESULTS: Maximal accuracy was achieved with score thresholds of 8 and higher and of 3 and higher for PI-RADS and Likert scales, respectively. At these thresholds, in the PZ, similar accuracy was achieved with the PI-RADS scale and the Likert scale for radiologist 1 (89.0% vs 88.2%, P = .223) and radiologist 3 (88.5% vs 88.2%, P = .739) and greater accuracy was achieved with the PI-RADS scale than the Likert scale for radiologist 2 (89.6% vs 87.1%, P = .008). In the TZ, accuracy was lower with the PI-RADS scale than with the Likert scale for radiologist 1 (70.0% vs 87.1%, P < .001), radiologist 2 (87.6% vs 92.6%, P = .002), and radiologist 3 (82.9% vs 91.2%, P < .001). For tumors with Gleason score of at least 7, sensitivity was higher with the PI-RADS scale than with the Likert scale for radiologist 1 (88.6% vs 82.6%, P = .032), and sensitivity was similar for radiologist 2 (78.0% vs 76.5, P = .467) and radiologist 3 (77.3% vs 81.1%, P = .125). CONCLUSION: Radiologists performed well with both PI-RADS and Likert scales for tumor localization, although, in the TZ, performance was better with the Likert scale than the PI-RADS scale. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122233/-/DC1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PI-RADS Prostate Imaging – Reporting and Data System: 2015, Version 2
Weinreb, J. C., Barentsz, J. O., Choyke, P. L., Cornud, F., Haider, M. A., Macura, K. J., Margolis, D., Schnall, M. D., Shtern, F., Tempany, C. M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.08.052 · Cited by 2,951
Cury, R. C., Abbara, S., Achenbach, S., Agatston, A., Berman, D. S., Budoff, M. J., Dill, K. E., Jacobs, J. E., Maroules, C. D., Rubin, G. D., et al. (2016) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2016.04.005 · Cited by 655
CAD-RADS™: Coronary Artery Disease – Reporting and Data System
Cury, R. C., Abbara, S., Achenbach, S., Agatston, A., Berman, D. S., Budoff, M. J., Dill, K. E., Jacobs, J. E., Maroules, C. D., Rubin, G. D., et al. (2016) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2016.04.024 · Cited by 507
Rosenkrantz, A. B., Ginocchio, L. A., Cornfeld, D., Froemming, A. T., Gupta, R. T., Turkbey, B., Westphalen, A. C., Babb, J. S., & Margolis, D. J. (2016) · Radiology · doi:10.1148/radiol.2016152542 · Cited by 501
Self-citationMultiparametric MRI for prostate cancer diagnosis: current status and future directions
Stabile, A., Giganti, F., Rosenkrantz, A. B., Taneja, S. S., Villeirs, G., Gill, I. S., Allen, C., Emberton, M., Moore, C. M., & Kasivisvanathan, V. (2020) · Nature Reviews Urology · doi:10.1038/s41585-019-0212-4 · Cited by 398
Self-citation
Metadata
- Authors
- Rosenkrantz, A. B., Kim, S., Lim, R. P., Hindman, N., Deng, F.-M., Babb, J. S., & Taneja, S. S.
- Venue
- Radiology
- Published
- 2013-11
- Volume
- 269
- Issue
- 2
- Pages
- 482-492
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2154430716
- Cited by
- 267
- References
- 0
- FWCI
- 31.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prostate Cancer Localization Using Multiparametric MR Imaging: Comparison of Prostate Imaging Reporting and Data System (PI-RADS) and Likert Scales. https://app.cochat.ai/papers/10.1148/radiol.13122233
- The paper
- Rosenkrantz, A. B., Kim, S., Lim, R. P., Hindman, N., Deng, F.-M., Babb, J. S., & Taneja, S. S. (2013). Prostate Cancer Localization Using Multiparametric MR Imaging: Comparison of Prostate Imaging Reporting and Data System (PI-RADS) and Likert Scales. Radiology. https://doi.org/10.1148/radiol.13122233
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.