The DOI matches its Crossref record.
Breast Cancer Detected with Screening US: Reasons for Nondetection at Mammography
Abstract
PURPOSE: To retrospectively review the mammograms of women with breast cancers detected at screening ultrasonography (US) to determine the reasons for nondetection at mammography. MATERIALS AND METHODS: This study received institutional review board approval, and informed consent was waived. Between 2003 and 2011, a retrospective database review revealed 335 US-depicted cancers in 329 women (median age, 47 years; age range, 29-69 years) with Breast Imaging Reporting and Data System breast density type 2-4. Five blinded radiologists independently reviewed the mammograms to determine whether the findings on negative mammograms should be recalled. Three unblinded radiologists re-reviewed the mammograms to determine the reasons for nondetection by using the reference location of the cancer on mammograms obtained after US-guided wire localization or breast magnetic resonance imaging. The number of cancers recalled by the blinded radiologists were compared with the reasons for nondetection determined by the unblinded radiologists. RESULTS: Of the 335 US-depicted cancers, 63 (19%) were recalled by three or more of the five blinded radiologists, and 272 (81%) showed no mammographic findings that required immediate action. In the unblinded repeat review, 263 (78%) cancers were obscured by overlapping dense breast tissue, and nine (3%) were not included at mammography owing to difficult anatomic location or poor positioning. Sixty-three (19%) cancers were considered interpretive errors. Of these, 52 (82%) were seen as subtle findings (46 asymmetries, six calcifications) and 11 (18%) were evident (six focal asymmetries, one distortion, four calcifications). CONCLUSION: Most breast cancers (81%) detected at screening US were not seen at mammography, even in retrospect. In addition, 19% had subtle or evident findings missed at mammography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Detecting and classifying lesions in mammograms with Deep Learning
Ribli, D., Horváth, A., Unger, Z., Pollner, P., & Csabai, I. (2018) · Scientific Reports · doi:10.1038/s41598-018-22437-z · Cited by 696
An overview of mammographic density and its association with breast cancer
Nazari, S. S., & Mukherjee, P. (2018) · Breast Cancer · doi:10.1007/s12282-018-0857-5 · Cited by 298
Metadata
- Authors
- Bae, M. S., Moon, W. K., Chang, J. M., Koo, H. R., Kim, W. H., Cho, N., Yi, A., La Yun, B., Lee, S. H., Kim, M. Y., Ryu, E. B., & Seo, M.
- Venue
- Radiology
- Published
- 2014-02
- Volume
- 270
- Issue
- 2
- Pages
- 369-377
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2101668496
- Cited by
- 174
- References
- 0
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breast Cancer Detected with Screening US: Reasons for Nondetection at Mammography. https://app.cochat.ai/papers/10.1148/radiol.13130724
- The paper
- Bae, M. S., Moon, W. K., Chang, J. M., Koo, H. R., Kim, W. H., Cho, N., Yi, A., La Yun, B., Lee, S. H., Kim, M. Y., Ryu, E. B., & Seo, M. (2014). Breast Cancer Detected with Screening US: Reasons for Nondetection at Mammography. Radiology. https://doi.org/10.1148/radiol.13130724
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.