The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
C-Arm Cone-Beam CT-guided Percutaneous Transthoracic Needle Biopsy of Lung Nodules: Clinical Experience in 1108 Patients
Abstract
PURPOSE: To retrospectively evaluate the diagnostic performance and complications of C-arm cone-beam computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) in 1108 patients. MATERIALS AND METHODS: This retrospective study was approved by the institutional review board with waiver of patient informed consent. From January 2009 to December 2011, 1108 patients (633 male, 475 female; mean age, 62.4 years ± 12.3 [standard deviation]) with 1116 pulmonary lesions (mean size, 2.7 cm ± 1.7) underwent 1153 cone-beam CT-guided PTNBs. A coaxial system with 18-gauge cutting needles was used. Diagnostic performance, complication rate, influencing factors, and patient radiation exposure were investigated. Variables influencing diagnostic performance and complications were assessed by using uni- and multivariate logistic regression analyses. RESULTS: Among 1153 PTNBs, pathologic analysis showed 1148 (99.6%) were technically successful (766 malignant [66.4%], 323 benign [28.0%], and 59 [5.1%] indeterminate). Sensitivity, specificity, and accuracy for diagnosis of malignancy were 95.7% (733 of 766), 100% (323 of 323), and 97.0% (1056 of 1089), respectively. In regard to diagnostic failures (five technical failures, 33 false-negative findings), lesions 1 cm in diameter or smaller and lesions in the lower lobe were significant risk factors (P = .028 and P = .034, respectively). As for complications, pneumothorax and hemoptysis occurred in 196 (17.0%) and 80 (6.9%) procedures, respectively. Multivariate analysis revealed two or more pleural passages and emphysema along the needle pathway were the two most significant risk factors for pneumothorax, and ground-glass nodules were the most significant risk factor for hemoptysis (P < .001 for all). Virtual guidance was a significant protective factor for both pneumothorax and hemoptysis (P < .001 for both). Mean estimated effective radiation dose through cone-beam CT-guided PTNBs was 7.3 mSv ± 4.1. CONCLUSION: Cone-beam CT-guided PTNB is a highly accurate and safe technique with which to diagnose pulmonary lesions with reasonable radiation exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hosmer, D. W., & Lemeshow, S. (2000) · doi:10.1002/0471722146 · Cited by 20,302
Cited by
Planchard, D., Popat, S., Kerr, K., Novello, S., Smit, E. F., Faivre-Finn, C., Mok, T. S., Reck, M., Van Schil, P. E., Hellmann, M. D., et al. (2018) · Annals of Oncology · doi:10.1093/annonc/mdy275 · Cited by 2,274
“The most significant disadvantage of transthoracic needle biopsy is a procedural risk of pneumothorax, ranging from 17% to 50% [37, 38].”
BackgroundWu, Y.-L., Planchard, D., Lu, S., Sun, H., Yamamoto, N., Kim, D.-W., Tan, D. S. W., Yang, J. C.-H., Azrif, M., Mitsudomi, T., et al. (2019) · Annals of Oncology · doi:10.1093/annonc/mdy554 · Cited by 291
Park, S., Lee, S. M., Kim, N., Choe, J., Cho, Y., Do, K.-H., & Seo, J. B. (2019) · European Radiology · doi:10.1007/s00330-019-06130-x · Cited by 71
Self-citation
Metadata
- Authors
- Lee, S. M., Park, C. M., Lee, K. H., Bahn, Y. E., Kim, J. I., & Goo, J. M.
- Venue
- Radiology
- Published
- 2014-04
- Volume
- 271
- Issue
- 1
- Pages
- 291-300
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2145790229
- Cited by
- 207
- References
- 1
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.