Radiation Dose Index of Renal Colic Protocol CT Studies in the United States: A Report from the American College of Radiology National Radiology Data Registry
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: To determine radiation dose indexes for computed tomography (CT) performed with renal colic protocols in the United States, including frequency of reduced-dose technique usage and any institutional-level factors associated with high or low dose indexes. MATERIALS AND METHODS: The Dose Imaging Registry (DIR) collects deidentified CT data, including examination type and dose indexes, for CT performed at participating institutions; thus, the DIR portion of the study was exempt from institutional review board approval and was HIPAA compliant. CT dose indexes were examined at the institutional level for CT performed with a renal colic protocol at institutions that contributed at least 10 studies to the registry as of January 2013. Additionally, patients undergoing CT for renal colic at a single institution (with institutional review board approval and informed consent from prospective subjects and waiver of consent from retrospective subjects) were studied to examine individual renal colic CT dose index patterns and explore relationships between patient habitus, demographics, and dose indexes. Descriptive statistics were used to analyze dose indexes, and linear regression and Spearman correlations were used to examine relationships between dose indexes and institutional factors. RESULTS: There were 49 903 renal colic protocol CT examinations conducted at 93 institutions between May 2011 and January 2013. Mean age ± standard deviation was 49 years ± 18, and 53.9% of patients were female. Institutions contributed a median of 268 (interquartile range, 77-699) CT studies. Overall mean institutional dose-length product (DLP) was 746 mGy ⋅ cm (effective dose, 11.2 mSv), with a range of 307-1497 mGy ⋅ cm (effective dose, 4.6-22.5 mSv) for mean DLPs. Only 2% of studies were conducted with a DLP of 200 mGy ⋅ cm or lower (a "reduced dose") (effective dose, 3 mSv), and only 10% of institutions kept DLP at 400 mGy ⋅ cm (effective dose, 6 mSv) or less in at least 50% of patients. CONCLUSION: Reduced-dose renal protocol CT is used infrequently in the United States. Mean dose index is higher than reported previously, and institutional variation is substantial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moore, C. L., Bomann, S., Daniels, B., Luty, S., Molinaro, A., Singh, D., & Gross, C. P. (2014) · BMJ · doi:10.1136/bmj.g2191 · Cited by 157
Self-citationBos, D., Yu, S., Luong, J., Chu, P., Wang, Y., Einstein, A. J., Starkey, J., Delman, B. N., Duong, P.-A. T., Das, M., et al. (2022) · European Radiology · doi:10.1007/s00330-021-08266-1 · Cited by 64
Smith-Bindman, R., Wang, Y., Yellen-Nelson, T. R., Moghadassi, M., Wilson, N., Gould, R., Seibert, A., Boone, J. M., Krishnam, M., Lamba, R., et al. (2017) · Radiology · doi:10.1148/radiol.2016151391 · Cited by 44
Metadata
- Authors
- Lukasiewicz, A., Bhargavan-Chatfield, M., Coombs, L., Ghita, M., Weinreb, J., Gunabushanam, G., & Moore, C. L.
- Venue
- Radiology
- Published
- 2014-05
- Volume
- 271
- Issue
- 2
- Pages
- 445-451
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2169539880
- Cited by
- 106
- References
- 0
- FWCI
- 13.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiation Dose Index of Renal Colic Protocol CT Studies in the United States: A Report from the American College of Radiology National Radiology Data Registry. https://app.cochat.ai/papers/10.1148/radiol.14131601
- The paper
- Lukasiewicz, A., Bhargavan-Chatfield, M., Coombs, L., Ghita, M., Weinreb, J., Gunabushanam, G., & Moore, C. L. (2014). Radiation Dose Index of Renal Colic Protocol CT Studies in the United States: A Report from the American College of Radiology National Radiology Data Registry. Radiology. https://doi.org/10.1148/radiol.14131601
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.