Cited by 38Medical Image Segmentation TechniquesUltrasound Imaging and ElastographyUltrasound in Clinical Applications

A technique for the estimation of fractional moving blood volume by using three-dimensional power Doppler US

Stevenson, Gordon N., Collins, Sally L., Welsh, Alec W., Impey, Lawrence W., Noble, J. Alison·2015·Radiology

Abstract

PURPOSE: To (a) demonstrate an image-processing method that can automatically measure the power Doppler signal in a three-dimensional ( 3D three-dimensional ) ultrasonographic (US) volume by using the location of organs within the image and (b) compare 3D three-dimensional fractional moving blood volume ( FMBV fractional moving blood volume ) results with commonly used, unstandardized measures of 3D three-dimensional power Doppler by using the human placenta as the organ of interest. MATERIALS AND METHODS: This is a retrospective study of scans obtained as part of a prospective study of imaging placental biomarkers with US, performed with ethical approval and written informed consent. One hundred forty-three consecutive female patients were examined by using an image-processing technique. Three-dimensional FMBV fractional moving blood volume was measured on the vasculature from the uteroplacental interface to a depth 5 mm into the placenta by using a normalization volume 10 mm outside the uteroplacental interface and compared against the Virtual Organ Computer-aided AnaLysis ( VOCAL Virtual Organ Computer-aided AnaLysis ; GE Healthcare, Milwaukee, Wis) vascularization flow index ( VFI vascularization flow index ). Intra- and interobserver variability was assessed in a subset of 18 volumes. Wilcoxon signed rank test and intraclass correlation coefficients were used to assess measurement repeatability. RESULTS: The mean 3D three-dimensional FMBV fractional moving blood volume value ± standard deviation was 11.78% ± 9.30 (range, 0.012%-44.16%). Mean VFI vascularization flow index was 2.26 ± 0.96 (range, 0.15-6.06). Linear regression of VFI vascularization flow index versus FMBV fractional moving blood volume produced an R(2) value of 0.211 and was significantly different in distribution (P < .001). Intraclass correlation coefficient analysis showed higher FMBV fractional moving blood volume values than VFI vascularization flow index for intra- and interobserver variability; intraobserver values were 0.95 for FMBV fractional moving blood volume (95% confidence interval [ CI confidence interval ]: 0.90, 0.98) versus 0.899 for VFI vascularization flow index (95% CI confidence interval : 0.78, 0.96), and interobserver values were 0.93 for FMBV fractional moving blood volume (95% CI confidence interval : 0.82, 0.97) versus 0.67 for VFI vascularization flow index (95% CI confidence interval : 0.32, 0.86). CONCLUSION: The extension of an existing two-dimensional standardized power Doppler measurement into 3D three-dimensional by using an image-processing technique was shown in an in utero placental study. Three-dimensional FMBV fractional moving blood volume and VFI vascularization flow index produced significantly different results. FMBV fractional moving blood volume performed better than VFI vascularization flow index in repeatability studies. Further studies are needed to assess accuracy against a reference standard.

Integrity signals

Registry

Crossref · 10.1148/radiol.14132363

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 29 · Cited by 38

Authors
Stevenson, G. N., Collins, S. L., Welsh, A. W., Impey, L. W., & Noble, J. A.
Affiliations
  • Royal Hospital for Women (AU)
  • John Radcliffe Hospital (GB)
  • University of Oxford (GB)
Venue
Radiology
Published
2015-01
Volume
274
Issue
1
Pages
230-237
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2004058198
Cited by
38
References
29
Citations by year
2026: 1 · 2024: 3 · 2022: 1 · 2021: 8 · 2020: 6 · 2019: 5 · 2018: 3 · 2017: 3 · 2016: 2 · 2015: 6
FWCI
3.28
Type
journal article
Language
en
Open access
closed
Locations
  • Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
Keywords
three-dimensional power Doppler ultrasound, placental vascularization, uteroplacental interface, vascularization flow index, placental biomarkers, repeatability, observer variability, fetal growth restriction, preeclampsia, placental insufficiency
MeSH terms
Adolescent, Adult, Blood Flow Velocity, Blood Volume, Female, Humans, Image Interpretation, Computer-Assisted, Placenta, Pregnancy, Prospective Studies, Reproducibility of Results, Ultrasonography, Doppler, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›