CoChat

Prostate Cancer: Diagnostic Performance of Real-time Shear-Wave Elastography

Correas, Jean-Michel, Tissier, Anne-Marie, Khairoune, Ahmed, Vassiliu, Viorel, Méjean, Arnaud, Hélénon, Olivier, Memo, Richard, Barr, Richard G. · 2015 · Radiology
Cited by 165

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively evaluate the performance of real-time ultrasonographic (US) shear-wave elastography (SWE) in the diagnosis of peripheral zone prostate cancer in patients with high and/or increasing prostate-specific antigen levels and/or abnormal digital rectal examination results. MATERIALS AND METHODS: After signing an informed consent form, men referred for transrectal prostate biopsy were enrolled in this prospective HIPAA-compliant two-center study, which was conducted with institutional review board approval. Transrectal US SWE of the prostate was performed after a conventional transrectal US examination and immediately before US-guided 12-core sextant biopsy. For each sextant, the maximum SWE value was measured and matched to the pathologic results of that sextant biopsy. The diagnostic performance of SWE was assessed at both patient and sextant levels. The elasticity value maximizing the Youden index was used to derive sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: The elasticity values were matched to pathologic results for a total of 1040 peripheral zone sextants in 184 men. One hundred twenty-nine positive biopsy findings (size, ≥3 mm; Gleason score, ≥6) were identified in 68 patients. The sextant-level sensitivity, specificity, PPV, NPV, and area under the receiver operating characteristic curve for SWE with a cutoff of 35 kPa for differentiating benign from malignant lesions were 96% (95% confidence interval [CI]: 95%, 97%), 85% (95% CI: 83%, 87%), 48% (95% CI: 46%, 50%), 99% (95% CI: 98%, 100%), and 95% (95% CI: 93%, 97%), respectively. CONCLUSION: Use of a 35-kPa threshold at SWE may provide additional information for the detection and biopsy guidance of prostate cancer, enabling a substantial reduction in the number of biopsies while ensuring that few peripheral zone adenocarcinomas are missed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.14140567

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 165

Metadata

Authors
Correas, J.-M., Tissier, A.-M., Khairoune, A., Vassiliu, V., Méjean, A., Hélénon, O., Memo, R., & Barr, R. G.
Venue
Radiology
Published
2015-04
Volume
275
Issue
1
Pages
280-289
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2160228139
Cited by
165
References
1
FWCI
8.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.