Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Blood Flow Vortices along the Main Pulmonary Artery Measured with MR Imaging for Diagnosis of Pulmonary Hypertension

Reiter, Gert, Reiter, Ursula, Kovacs, Gabor, Olschewski, Horst, Fuchsjäger, Michael · 2015 · Radiology

Abstract

PURPOSE: To approximate the functional relationship between invasively measured mean pulmonary arterial pressure (mPAP) and the phase-contrast magnetic resonance (MR) imaging-derived duration of vortical blood flow along the main pulmonary artery and to analyze its applicability for noninvasive diagnosis of pulmonary hypertension (PH) and borderline mPAP. MATERIALS AND METHODS: The local ethics review board approved this prospective study of 145 patients suspected of having PH (69 patients with PH, 19 patients with borderline mPAP, and 57 patients with normal mPAP) who underwent right heart catheterization (RHC) and three-directional phase-contrast MR imaging of the main pulmonary artery. Velocity fields were viewed with dedicated software and evaluated for the duration of vortical blood flow in the main pulmonary artery (tvortex, the percentage of cardiac phases with vortex present). The relationship between mPAP at RHC and tvortex was assessed by means of a segmented linear regression model, and by Bland-Altman and receiver operating characteristic curve analyses. RESULTS: The relationship between mPAP and tvortex was described adequately (R(2) = 0.95) as linearly increasing, from tvortex of 0% (mPAP ≤ 16.0 mm Hg) with a slope of 1.59% per millimeter of mercury. The standard deviation between mPAP values derived from RHC and those estimated by using tvortex was 3.9 mm Hg. The area under the curve for tvortex-based diagnosis of PH was 0.994 (95% confidence interval [CI]: 0.982, 0.998), and the calculated PH cut-off value (tvortex ≥ 14.3%) resulted in sensitivity of 0.97 (95% CI: 0.90, 0.99) and specificity of 0.96 (95% CI: 0.89, 0.99). Vortical blood flow with tvortex less than 14.3% was specific for borderline mPAP. CONCLUSION: Duration of vortical blood flow in the main pulmonary artery that is determined by using phase-contrast MR imaging allows accurate estimation of elevated mPAP and diagnosis of PH. Clinical trial registration no. NCT00575692.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.14140849

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 174

Metadata

Authors
Reiter, G., Reiter, U., Kovacs, G., Olschewski, H., & Fuchsjäger, M.
Venue
Radiology
Published
2015-04
Volume
275
Issue
1
Pages
71-79
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2159194787
Cited by
174
References
2
FWCI
5.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blood Flow Vortices along the Main Pulmonary Artery Measured with MR Imaging for Diagnosis of Pulmonary Hypertension. https://app.cochat.ai/papers/10.1148/radiol.14140849
The paper
Reiter, G., Reiter, U., Kovacs, G., Olschewski, H., & Fuchsjäger, M. (2015). Blood Flow Vortices along the Main Pulmonary Artery Measured with MR Imaging for Diagnosis of Pulmonary Hypertension. Radiology. https://doi.org/10.1148/radiol.14140849

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.