Early Small-Bowel Ischemia: Dual-Energy CT Improves Conspicuity Compared with Conventional CT in a Swine Model

Potretzke, Theodora A., Brace, Christopher L., Lubner, Meghan G., Sampson, Lisa A., Willey, Bridgett J., Lee, Fred T. · 2015 · Radiology
Cited by 104

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: To compare dual-energy computed tomography (CT) with conventional CT for the detection of small-bowel ischemia in an experimental animal model. MATERIALS AND METHODS: The study was approved by the animal care and use committee and was performed in accordance with the Guide for Care and Use of Laboratory Animals issued by the National Research Council. Ischemic bowel segments (n = 8) were created in swine (n = 4) by means of surgical occlusion of distal mesenteric arteries and veins. Contrast material-enhanced dual-energy CT and conventional single-energy CT (120 kVp) sequences were performed during the portal venous phase with a single-source fast-switching dual-energy CT scanner. Attenuation values and contrast-to-noise ratios of ischemic and perfused segments on iodine material-density, monospectral dual-energy CT (51 keV, 65 keV, and 70 keV), and conventional 120-kVp CT images were compared. Linear mixed-effects models were used for comparisons. RESULTS: The attenuation difference between ischemic and perfused segments was significantly greater on dual-energy 51-keV CT images than on conventional 120-kVp CT images (mean difference, 91.7 HU vs 47.6 HU; P < .0001). Conspicuity of ischemic segments was significantly greater on dual-energy iodine material-density and 51-keV CT images than on 120-kVp CT images (mean contrast-to-noise ratios, 4.9, 4.3, and 2.1, respectively; P < .0001). Although attenuation differences on dual-energy 65- and 70-keV CT images were not significantly different from those on 120-kVp images (55.0 HU, 45.8 HU, and 47.6 HU, respectively; 65 keV vs 120 kVp, P = .15; 70 keV vs 120 kVp, P = .46), the contrast-to-noise ratio was greater for the 65- and 70-keV images than for the 120-kVp images (4.4, 4.1, and 2.1 respectively; P < .0005). CONCLUSION: Dual-energy CT significantly improved the conspicuity of the ischemic bowel compared with conventional CT by increasing attenuation differences between ischemic and perfused segments on low-kiloelectron volt and iodine material density images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.14140875

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 104

Metadata

Authors
Potretzke, T. A., Brace, C. L., Lubner, M. G., Sampson, L. A., Willey, B. J., & Lee, F. T.
Venue
Radiology
Published
2015-04
Volume
275
Issue
1
Pages
119-126
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2141152233
Cited by
104
References
2
FWCI
3.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early Small-Bowel Ischemia: Dual-Energy CT Improves Conspicuity Compared with Conventional CT in a Swine Model. https://app.cochat.ai/papers/10.1148/radiol.14140875
The paper
Potretzke, T. A., Brace, C. L., Lubner, M. G., Sampson, L. A., Willey, B. J., & Lee, F. T. (2015). Early Small-Bowel Ischemia: Dual-Energy CT Improves Conspicuity Compared with Conventional CT in a Swine Model. Radiology. https://doi.org/10.1148/radiol.14140875

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.