Dual-Energy CT for the Musculoskeletal System
Abstract
The principal advantages of dual-energy computed tomography (CT) over conventional CT in the musculoskeletal setting relate to the additional information provided regarding tissue composition, artifact reduction, and image optimization. This article discusses the manifestations of these in clinical practice-urate and bone marrow edema detection, metal artifact reduction, and tendon analysis, with potential in arthrography, bone densitometry, and metastases surveillance. The basic principles of dual-energy CT physics and scanner design will also be discussed. © RSNA, 2016.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
DECT uses virtual non-calcium imaging to enable material breakdown and visualization of bone marrow edema-like signal intensity.
“While conventional CT emphasizes subchondral sclerosis, osteophytes, and cysts, DECT uses virtual non-calcium imaging to enable the material breakdown and visualization of bone marrow edema-like signal intensity (ELMSI) [75].”
From Biomarker-Guided Imaging and AI-Augmented Diagnosis of Degenerative Joint Disease (2025) · cites this paper as [75]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 122 · Cited by 242
- Authors
- Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A.
- Affiliations
- University of British Columbia (CA)
- Venue
- Radiology
- Published
- 2016-12
- Volume
- 281
- Issue
- 3
- Pages
- 690-707
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2551262871
- Cited by
- 242
- References
- 122
- Citations by year
- 2026: 9 · 2025: 20 · 2024: 33 · 2023: 25 · 2022: 28 · 2021: 23 · 2020: 42 · 2019: 27 · 2018: 23 · 2017: 12
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Keywords
- dual-energy CT, musculoskeletal imaging, bone marrow edema, metal artifact reduction, tendon imaging, arthrography, bone densitometry, CT scanner design, tissue composition
- MeSH terms
- Adult, Aged, Arthrography, Bone Marrow Diseases, Collagen, Edema, Female, Gout, Humans, Intervertebral Disc, Ligaments, Male, Metals, Middle Aged, Musculoskeletal Diseases, Musculoskeletal System, Tomography, X-Ray Computed, Uric Acid, Bone Density, Radiography, Dual-Energy Scanned Projection, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review