Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 180

The DOI matches its Crossref record.

High-Risk Breast Lesions: A Machine Learning Model to Predict Pathologic Upgrade and Reduce Unnecessary Surgical Excision

Bahl, Manisha, Barzilay, Regina, Yedidia, Adam B., Locascio, Nicholas J., Yu, Lili, Lehman, Constance D. · 2018 · Radiology

Abstract

Purpose To develop a machine learning model that allows high-risk breast lesions (HRLs) diagnosed with image-guided needle biopsy that require surgical excision to be distinguished from HRLs that are at low risk for upgrade to cancer at surgery and thus could be surveilled. Materials and Methods Consecutive patients with biopsy-proven HRLs who underwent surgery or at least 2 years of imaging follow-up from June 2006 to April 2015 were identified. A random forest machine learning model was developed to identify HRLs at low risk for upgrade to cancer. Traditional features such as age and HRL histologic results were used in the model, as were text features from the biopsy pathologic report. Results One thousand six HRLs were identified, with a cancer upgrade rate of 11.4% (115 of 1006). A machine learning random forest model was developed with 671 HRLs and tested with an independent set of 335 HRLs. Among the most important traditional features were age and HRL histologic results (eg, atypical ductal hyperplasia). An important text feature from the pathologic reports was “severely atypical.” Instead of surgical excision of all HRLs, if those categorized with the model to be at low risk for upgrade were surveilled and the remainder were excised, then 97.4% (37 of 38) of malignancies would have been diagnosed at surgery, and 30.6% (91 of 297) of surgeries of benign lesions could have been avoided. Conclusion This study provides proof of concept that a machine learning model can be applied to predict the risk of upgrade of HRLs to cancer. Use of this model could decrease unnecessary surgery by nearly one-third and could help guide clinical decision making with regard to surveillance versus surgical excision of HRLs. © RSNA, 2017

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2017170549

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 35

  1. 10.1016/S0140-6736(85)92204-4 · DOI · Paper page
  2. 10.1016/0140-6736(93)91067-V · DOI · Paper page
  3. 10.1001/jama.2015.13183 · DOI · Paper page
  4. 10.7326/M15-0970 · DOI · Paper page
  5. 10.2214/AJR.08.1342 · doi:10.2214/ajr.08.1342
  6. 10.1002/cncr.29199 · DOI
  7. 10.2214/AJR.08.2227 · doi:10.2214/ajr.08.2227
  8. 10.2214/AJR.11.7799 · DOI
  9. 10.2214/AJR.07.2768 · doi:10.2214/ajr.07.2768
  10. 10.1016/j.amjsurg.2007.07.038 · doi:10.1016/j.amjsurg.2007.07.038
  11. 10.2214/AJR.07.2664 · doi:10.2214/ajr.07.2664
  12. 10.1016/j.rcl.2010.06.004 · doi:10.1016/j.rcl.2010.06.004
  13. 10.1245/s10434-010-1127-8 · doi:10.1245/s10434-010-1127-8
  14. 10.2214/AJR.10.5265 · doi:10.2214/ajr.10.5265
  15. 10.1016/j.ejca.2011.08.011 · DOI
  16. 10.2214/AJR.11.7043 · doi:10.2214/ajr.11.7043
  17. 10.1016/j.jamcollsurg.2011.12.005 · doi:10.1016/j.jamcollsurg.2011.12.005
  18. 10.1245/s10434-012-2534-9 · doi:10.1245/s10434-012-2534-9
  19. 10.1097/COC.0b013e3182354a3f · doi:10.1097/coc.0b013e3182354a3f
  20. 10.1038/modpathol.2012.221 · doi:10.1038/modpathol.2012.221
  21. 10.5858/arpa.2012-0297-OA · doi:10.5858/arpa.2012-0297-oa
  22. 10.1245/s10434-012-2846-9 · doi:10.1245/s10434-012-2846-9
  23. 10.1038/modpathol.2015.128 · doi:10.1038/modpathol.2015.128
  24. 10.5858/arpa.2014-0550-OA · doi:10.5858/arpa.2014-0550-oa
  25. 10.1016/j.anndiagpath.2014.12.003 · doi:10.1016/j.anndiagpath.2014.12.003
  26. 10.1201/b16812-42 · DOI
  27. 10.2214/AJR.16.17224 · DOI · Paper page
  28. 10.1002/0471200611 · DOI · Paper page
  29. 10.2214/AJR.11.7717 · doi:10.2214/ajr.11.7717
  30. 10.2214/AJR.13.11862 · doi:10.2214/ajr.13.11862
  31. 10.1016/j.amjsurg.2013.05.014 · doi:10.1016/j.amjsurg.2013.05.014
  32. 10.1007/s10549-011-1839-x · doi:10.1007/s10549-011-1839-x
  33. 10.1007/s00428-012-1312-1 · doi:10.1007/s00428-012-1312-1
  34. 10.1038/srep27327 · DOI · Paper page
  35. Sickles EA, 2013, Breast Imaging Reporting and Data System

Cited by

See all 180

Metadata

Authors
Bahl, M., Barzilay, R., Yedidia, A. B., Locascio, N. J., Yu, L., & Lehman, C. D.
Venue
Radiology
Published
2018-03
Volume
286
Issue
3
Pages
810-818
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2767142522
Cited by
180
References
0
FWCI
10.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Risk Breast Lesions: A Machine Learning Model to Predict Pathologic Upgrade and Reduce Unnecessary Surgical Excision. https://app.cochat.ai/papers/10.1148/radiol.2017170549
The paper
Bahl, M., Barzilay, R., Yedidia, A. B., Locascio, N. J., Yu, L., & Lehman, C. D. (2018). High-Risk Breast Lesions: A Machine Learning Model to Predict Pathologic Upgrade and Reduce Unnecessary Surgical Excision. Radiology. https://doi.org/10.1148/radiol.2017170549

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.