CoChat

Deep Learning for MR Angiography: Automated Detection of Cerebral Aneurysms

Ueda, Daiju, Yamamoto, Akira, Nishimori, Masataka, Shimono, Taro, Doishita, Satoshi, Shimazaki, Akitoshi, Katayama, Yutaka, Fukumoto, Shinya, Choppin, Antoine, Shimahara, Yuki, Miki, Yukio · 2019 · Radiology
Cited by 233

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Purpose To develop and evaluate a supportive algorithm using deep learning for detecting cerebral aneurysms at time-of-flight MR angiography to provide a second assessment of images already interpreted by radiologists. Materials and Methods MR images reported by radiologists to contain aneurysms were extracted from four institutions for the period from November 2006 through October 2017. The images were divided into three data sets: training data set, internal test data set, and external test data set. The algorithm was constructed by deep learning with the training data set, and its sensitivity to detect aneurysms in the test data sets was evaluated. To find aneurysms that had been overlooked in the initial reports, two radiologists independently performed a blinded interpretation of aneurysm candidates detected by the algorithm. When there was disagreement, the final diagnosis was made in consensus. The number of newly detected aneurysms was also evaluated. Results The training data set, which provided training and validation data, included 748 aneurysms (mean size, 3.1 mm ± 2.0 [standard deviation]) from 683 examinations; 318 of these examinations were on male patients (mean age, 63 years ± 13) and 365 were on female patients (mean age, 64 years ± 13). Test data were provided by the internal test data set (649 aneurysms [mean size, 4.1 mm ± 3.2] in 521 examinations, including 177 male patients and 344 female patients with mean age of 66 years ± 12 and 67 years ± 13, respectively) and the external test data set (80 aneurysms [mean size, 4.1 mm ± 2.1] in 67 examinations, including 19 male patients and 48 female patients with mean age of 63 years ± 12 and 68 years ± 12, respectively). The sensitivity was 91% (592 of 649) and 93% (74 of 80) for the internal and external test data sets, respectively. The algorithm improved aneurysm detection in the internal and external test data sets by 4.8% (31 of 649) and 13% (10 of 80), respectively, compared with the initial reports. Conclusion A deep learning algorithm detected cerebral aneurysms in radiologic reports with high sensitivity and improved aneurysm detection compared with the initial reports. © RSNA, 2018 See also the editorial by Flanders in this issue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2018180901

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Ueda, D., Yamamoto, A., Nishimori, M., Shimono, T., Doishita, S., Shimazaki, A., Katayama, Y., Fukumoto, S., Choppin, A., Shimahara, Y., & Miki, Y.
Venue
Radiology
Published
2019-01
Volume
290
Issue
1
Pages
187-194
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2895926594
Cited by
233
References
4
FWCI
12.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.