Chest Radiograph Interpretation with Deep Learning Models: Assessment with Radiologist-adjudicated Reference Standards and Population-adjusted Evaluation

Abstract

Background Deep learning has the potential to augment the use of chest radiography in clinical radiology, but challenges include poor generalizability, spectrum bias, and difficulty comparing across studies. Purpose To develop and evaluate deep learning models for chest radiograph interpretation by using radiologist-adjudicated reference standards. Materials and Methods Deep learning models were developed to detect four findings (pneumothorax, opacity, nodule or mass, and fracture) on frontal chest radiographs. This retrospective study used two data sets. Data set 1 (DS1) consisted of 759 611 images from a multicity hospital network and ChestX-ray14 is a publicly available data set with 112 120 images. Natural language processing and expert review of a subset of images provided labels for 657 954 training images. Test sets consisted of 1818 and 1962 images from DS1 and ChestX-ray14, respectively. Reference standards were defined by radiologist-adjudicated image review. Performance was evaluated by area under the receiver operating characteristic curve analysis, sensitivity, specificity, and positive predictive value. Four radiologists reviewed test set images for performance comparison. Inverse probability weighting was applied to DS1 to account for positive radiograph enrichment and estimate population-level performance. Results In DS1, population-adjusted areas under the receiver operating characteristic curve for pneumothorax, nodule or mass, airspace opacity, and fracture were, respectively, 0.95 (95% confidence interval [CI]: 0.91, 0.99), 0.72 (95% CI: 0.66, 0.77), 0.91 (95% CI: 0.88, 0.93), and 0.86 (95% CI: 0.79, 0.92). With ChestX-ray14, areas under the receiver operating characteristic curve were 0.94 (95% CI: 0.93, 0.96), 0.91 (95% CI: 0.89, 0.93), 0.94 (95% CI: 0.93, 0.95), and 0.81 (95% CI: 0.75, 0.86), respectively. Conclusion Expert-level models for detecting clinically relevant chest radiograph findings were developed for this study by using adjudicated reference standards and with population-level performance estimation. Radiologist-adjudicated labels for 2412 ChestX-ray14 validation set images and 1962 test set images are provided. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Chang in this issue.

Overview

Integrity signals

Registry

Crossref · 10.1148/radiol.2019191293

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 30 references

Research works printed but not linked: 3

  1. Auffermann WF, 2019, AJR Am J Roentgenol, 1
  2. Summers RM, NIH Chest X-ray Dataset of 14 Common Thorax Disease Categories
  3. Chollet F. Xception: Deep Learning with Depthwise Separable Convolutions. In: 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Honolulu, July 21–26, 2017. Piscataway, NJ: IEEE, 2017; 1800–1807.

Cited by

See all 337

Metadata

Authors
Majkowska, A., Mittal, S., Steiner, D. F., Reicher, J. J., McKinney, S. M., Duggan, G. E., Eswaran, K., Cameron Chen, P.-H., Liu, Y., Kalidindi, S. R., Ding, A., Corrado, G. S., Tse, D., & Shetty, S.
Affiliations
  • Stanford Health Care (US)
  • From Google Health, 1600 Amphitheatre Pkwy, Mountain View, CA 94043 (A.M., S.M., D.F.S., S.M.M., G.E.D., K.E., P.H.C.C., Y.L., G.S.C., D.T., S.S.); Stanford Healthcare and Palo Alto Veterans Affairs, Palo Alto, Calif (J.J.R.); Apollo Radiology International, Hyderabad, India (S.R.K.); and California Advanced Imaging, Novato, Calif (A.D.).
Venue
Radiology
Published
2020-02
Volume
294
Issue
2
Pages
421-431
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2991676991
Cited by
277
References
30
Citations by year
2026: 21 · 2025: 37 · 2024: 36 · 2023: 48 · 2022: 48 · 2021: 52 · 2020: 34
FWCI
22.28
Type
journal article
Language
en
Open access
closed
Locations
  • Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › COVID-19 diagnosis using AI
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
chest X-ray interpretation, deep learning, pneumothorax detection, lung nodule detection, lung opacity, rib fracture detection, inverse probability weighting, spectrum bias, generalizability, ChestX-ray14, positive predictive value, sensitivity and specificity
MeSH terms
Radiologists, Deep Learning, Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Female, Humans, Infant, Male, Middle Aged, Pneumothorax, Radiographic Image Interpretation, Computer-Assisted, Reference Standards, Respiratory Tract Diseases, Retrospective Studies, Sensitivity and Specificity, Thoracic Injuries, Radiography, Thoracic, Reproducibility of Results, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Chest Radiograph Interpretation with Deep Learning Models: Assessment with Radiologist-adjudicated Reference Standards and Population-adjusted Evaluation. https://app.cochat.ai/papers/10.1148/radiol.2019191293
The paper
Majkowska, A., Mittal, S., Steiner, D. F., Reicher, J. J., McKinney, S. M., Duggan, G. E., Eswaran, K., Cameron Chen, P.-H., Liu, Y., Kalidindi, S. R., Ding, A., Corrado, G. S., Tse, D., & Shetty, S. (2020). Chest Radiograph Interpretation with Deep Learning Models: Assessment with Radiologist-adjudicated Reference Standards and Population-adjusted Evaluation. Radiology. https://doi.org/10.1148/radiol.2019191293

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.