Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Machine Learning for Detecting Early Infarction in Acute Stroke with Non–Contrast-enhanced CT

Qiu, Wu, Kuang, Hulin, Teleg, Ericka, Ospel, Johanna M., Sohn, Sung Il, Almekhlafi, Mohammed, Goyal, Mayank, Hill, Michael D., Demchuk, Andrew M., Menon, Bijoy K. · 2020 · Radiology

Abstract

Background Identifying the presence and extent of infarcted brain tissue at baseline plays a crucial role in the treatment of patients with acute ischemic stroke (AIS). Patients with extensive infarction are unlikely to benefit from thrombolysis or thrombectomy procedures. Purpose To develop an automated approach to detect and quantitate infarction by using non–contrast-enhanced CT scans in patients with AIS. Materials and Methods Non–contrast-enhanced CT images in patients with AIS (<6 hours from symptom onset to CT) who also underwent diffusion-weighted (DW) MRI within 1 hour after AIS were obtained from May 2004 to July 2009 and were included in this retrospective study. Ischemic lesions manually contoured on DW MRI scans were used as the reference standard. An automatic segmentation approach involving machine learning (ML) was developed to detect infarction. Randomly selected nonenhanced CT images from 157 patients with the lesion labels manually contoured on DW MRI scans were used to train and validate the ML model; the remaining 100 patients independent of the derivation cohort were used for testing. The ML algorithm was quantitatively compared with the reference standard (DW MRI) by using Bland-Altman plots and Pearson correlation. Results In 100 patients in the testing data set (median age, 69 years; interquartile range [IQR]: 59–76 years; 59 men), baseline non–contrast-enhanced CT was performed within a median time of 48 minutes from symptom onset (IQR, 27–93 minutes); baseline MRI was performed a median of 38 minutes (IQR, 24–48 minutes) later. The algorithm-detected lesion volume correlated with the reference standard of expert-contoured lesion volume in acute DW MRI scans (r = 0.76, P < .001). The mean difference between the algorithm-segmented volume (median, 15 mL; IQR, 9–38 mL) and the DW MRI volume (median, 19 mL; IQR, 5–43 mL) was 11 mL (P = .89). Conclusion A machine learning approach for segmentation of infarction on non–contrast-enhanced CT images in patients with acute ischemic stroke showed good agreement with stroke volume on diffusion-weighted MRI scans. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Nael in this issue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2020191193

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 195

Metadata

Authors
Qiu, W., Kuang, H., Teleg, E., Ospel, J. M., Sohn, S. I., Almekhlafi, M., Goyal, M., Hill, M. D., Demchuk, A. M., & Menon, B. K.
Venue
Radiology
Published
2020-03
Volume
294
Issue
3
Pages
638-644
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W3003775010
Cited by
195
References
1
FWCI
18.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Machine Learning for Detecting Early Infarction in Acute Stroke with Non–Contrast-enhanced CT. https://app.cochat.ai/papers/10.1148/radiol.2020191193
The paper
Qiu, W., Kuang, H., Teleg, E., Ospel, J. M., Sohn, S. I., Almekhlafi, M., Goyal, M., Hill, M. D., Demchuk, A. M., & Menon, B. K. (2020). Machine Learning for Detecting Early Infarction in Acute Stroke with Non–Contrast-enhanced CT. Radiology. https://doi.org/10.1148/radiol.2020191193

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.