CoChat

Deep Learning–based Detection of Solid and Cystic Pancreatic Neoplasms at Contrast-enhanced CT

Park, Hyo Jung, Shin, Keewon, You, Myung-Won, Kyung, Sung-Gu, Kim, So Yeon, Park, Seong Ho, Byun, Jae Ho, Kim, Namkug, Kim, Hyoung Jung · 2023 · Radiology
Cited by 67

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Background Deep learning (DL) may facilitate the diagnosis of various pancreatic lesions at imaging. Purpose To develop and validate a DL-based approach for automatic identification of patients with various solid and cystic pancreatic neoplasms at abdominal CT and compare its diagnostic performance with that of radiologists. Materials and Methods In this retrospective study, a three-dimensional nnU-Net–based DL model was trained using the CT data of patients who underwent resection for pancreatic lesions between January 2014 and March 2015 and a subset of patients without pancreatic abnormality who underwent CT in 2014. Performance of the DL-based approach to identify patients with pancreatic lesions was evaluated in a temporally independent cohort (test set 1) and a temporally and spatially independent cohort (test set 2) and was compared with that of two board-certified radiologists. Performance was assessed using receiver operating characteristic analysis. Results The study included 852 patients in the training set (median age, 60 years [range, 19–85 years]; 462 men), 603 patients in test set 1 (median age, 58 years [range, 18–82 years]; 376 men), and 589 patients in test set 2 (median age, 63 years [range, 18–99 years]; 343 men). In test set 1, the DL-based approach had an area under the receiver operating characteristic curve (AUC) of 0.91 (95% CI: 0.89, 0.94) and showed slightly worse performance in test set 2 (AUC, 0.87 [95% CI: 0.84, 0.89]). The DL-based approach showed high sensitivity in identifying patients with solid lesions of any size (98%–100%) or cystic lesions measuring 1.0 cm or larger (92%–93%), which was comparable with the radiologists (95%–100% for solid lesions [P = .51 to P > .99]; 93%–98% for cystic lesions ≥1.0 cm [P = .38 to P > .99]). Conclusion The deep learning–based approach demonstrated high performance in identifying patients with various solid and cystic pancreatic lesions at CT. © RSNA, 2022 Online supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.220171

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 67

Metadata

Authors
Park, H. J., Shin, K., You, M.-W., Kyung, S.-G., Kim, S. Y., Park, S. H., Byun, J. H., Kim, N., & Kim, H. J.
Venue
Radiology
Published
2023-01
Volume
306
Issue
1
Pages
140-149
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W4292723391
Cited by
67
References
9
FWCI
4.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep Learning–based Detection of Solid and Cystic Pancreatic Neoplasms at Contrast-enhanced CT. https://app.cochat.ai/papers/10.1148/radiol.220171
The paper
Park, H. J., Shin, K., You, M.-W., Kyung, S.-G., Kim, S. Y., Park, S. H., Byun, J. H., Kim, N., & Kim, H. J. (2023). Deep Learning–based Detection of Solid and Cystic Pancreatic Neoplasms at Contrast-enhanced CT. Radiology. https://doi.org/10.1148/radiol.220171

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.