The DOI matches its Crossref record.
Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast Center
Abstract
PURPOSE: To prospectively assess the effect of computer-aided detection (CAD) on the interpretation of screening mammograms in a community breast center. MATERIALS AND METHODS: Over a 12-month period, 12,860 screening mammograms were interpreted with the assistance of a CAD system. Each mammogram was initially interpreted without the assistance of CAD, followed immediately by a reevaluation of areas marked by the CAD system. Data were recorded to measure the effect of CAD on the recall rate, positive predictive value for biopsy, cancer detection rate, and stage of malignancies at detection. RESULTS: When comparing the radiologist's performance without CAD with that when CAD was used, the authors observed the following: (a) an increase in recall rate from 6.5% to 7.7%, (b) no change in the positive predictive value for biopsy at 38%, (c) a 19.5% increase in the number of cancers detected, and (d) an increase in the proportion of early-stage (0 and I) malignancies detected from 73% to 78%. CONCLUSION: The use of CAD in the interpretation of screening mammograms can increase the detection of early-stage malignancies without undue effect on the recall rate or positive predictive value for biopsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Artificial intelligence in cancer imaging: Clinical challenges and applications
Bi, W. L., Hosny, A., Schabath, M. B., Giger, M. L., Birkbak, N. J., Mehrtash, A., Allison, T., Arnaout, O., Abbosh, C., Dunn, I. F., et al. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21552 · Cited by 1,846
American Cancer Society Guidelines for Breast Cancer Screening: Update 2003
Smith, R. A., Saslow, D., Andrews Sawyer, K., Burke, W., Costanza, M. E., Evans, W. P., Foster, R. S., Hendrick, E., Eyre, H. J., & Sener, S. (2003) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.53.3.141 · Cited by 770
Detecting and classifying lesions in mammograms with Deep Learning
Ribli, D., Horváth, A., Unger, Z., Pollner, P., & Csabai, I. (2018) · Scientific Reports · doi:10.1038/s41598-018-22437-z · Cited by 696
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Metadata
- Authors
- Freer, T. W., & Ulissey, M. J.
- Venue
- Radiology
- Published
- 2001-09
- Volume
- 220
- Issue
- 3
- Pages
- 781-786
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2113115183
- Cited by
- 751
- References
- 0
- FWCI
- 30.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast Center. https://app.cochat.ai/papers/10.1148/radiol.2203001282
- The paper
- Freer, T. W., & Ulissey, M. J. (2001). Screening Mammography with Computer-aided Detection: Prospective Study of 12,860 Patients in a Community Breast Center. Radiology. https://doi.org/10.1148/radiol.2203001282
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.