US for Detecting Renal Calculi with Nonenhanced CT as a Reference Standard
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the sensitivity and specificity of ultrasonography (US) for detecting parenchymal and renal pelvis calculi and to establish the accuracy of US for determining the size and number of calculi. MATERIALS AND METHODS: A total of 123 US and computed tomographic (CT) examinations were compared retrospectively for the presence of renal calculi. The sensitivity of US was determined for individual calculi and at least one calculus per examination. Retrospective findings were compared with the original US interpretation. The sizes of calculi in longest axis were compared on US and CT images, and the US detection of calculi in the left and right kidneys was compared. The use of US for detecting the full extent of calculus burden was evaluated in patients with multiple calculi. RESULTS: US depicted 24 of 101 calculi identified at CT, yielding a sensitivity of 24% and a specificity of 90%. There was no substantial difference for the detection of calculi in the right and left kidneys. The sensitivity of US for any calculi in a patient was 44%, equal to that of the original US interpretation. US enabled identification of 39% of patients with multiple calculi and demonstrated all calculi in 17% of these patients. The mean size of calculi detected with US was 7.1 mm +/- 1.2 (95% CI); 73% of calculi not visualized at US were less than 3.0 mm in size. Calculus size based on US and CT measurements was concordant in 79% of cases and differed by a mean of 1.5 mm +/- 0.7. CONCLUSION: US is of limited value for detecting renal calculi.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acute flank pain: comparison of non-contrast-enhanced CT and intravenous urography.
Smith, R. C., Rosenfield, A. T., Choe, K. A., Essenmacher, K. R., Verga, M., Glickman, M. G., & Lange, R. C. (1995) · Radiology · doi:10.1148/radiology.194.3.7862980 · Cited by 671
Diagnosis of acute flank pain: value of unenhanced helical CT.
Smith, R. C., Verga, M., McCarthy, S., & Rosenfield, A. T. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.1.8571915 · Cited by 580
Cited by
Westphalen, A. C., Hsia, R. Y., Maselli, J. H., Wang, R., & Gonzales, R. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01103.x · Cited by 175
Wang, R. C., Rodriguez, R. M., Moghadassi, M., Noble, V., Bailitz, J., Mallin, M., Corbo, J., Kang, T. L., Chu, P., Shiboski, S., et al. (2016) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2015.08.019 · Cited by 68
Metadata
- Authors
- Fowler, K. A. B., Locken, J. A., Duchesne, J. H., & Williamson, M. R.
- Venue
- Radiology
- Published
- 2002-01
- Volume
- 222
- Issue
- 1
- Pages
- 109-113
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2083401635
- Cited by
- 289
- References
- 2
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: US for Detecting Renal Calculi with Nonenhanced CT as a Reference Standard. https://app.cochat.ai/papers/10.1148/radiol.2221010453
- The paper
- Fowler, K. A. B., Locken, J. A., Duchesne, J. H., & Williamson, M. R. (2002). US for Detecting Renal Calculi with Nonenhanced CT as a Reference Standard. Radiology. https://doi.org/10.1148/radiol.2221010453
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.