The DOI matches its Crossref record.
Computerized Detection of Colonic Polyps at CT Colonography on the Basis of Volumetric Features: Pilot Study
Abstract
PURPOSE: To develop a computer-aided diagnosis (CAD) scheme for automated detection of colonic polyps on the basis of volumetric features and to assess its accuracy on the basis of colonoscopy, the standard. MATERIALS AND METHODS: Computed tomographic (CT) colonography was performed in patients with use of standard bowel cleansing, air insufflation, and helical scanning in supine and prone positions. The colon was extracted from volumetric data sets generated from transverse CT sections. Volumetric features characterizing polyps were computed at each point in the extracted colon. Polyps were detected by means of hysteresis thresholding and fuzzy clustering followed by a rule-based test on the basis of feature values. Locations of the detected polyps were compared with those detected at conventional colonoscopy. RESULTS: Forty-one cases were analyzed: nine cases with polyps and 32 without polyps. Each case with polyps had one polyp of clinically important size (six were 5-9 mm; three, 10 mm). Thus, there were 82 volumetric data sets, 18 included polyps. Eighty-nine percent (16 of 18) of the polyps were detected. Each of the two false-negative findings was detected in the other position; thus, 100% of polyp cases were detected, with 2.5 false-positive findings per patient. The false-positive findings were similar to those due to common perceptual errors. Most of the false-positive findings were easily distinguishable from true polyps by experienced radiologists. CONCLUSION: The CAD scheme has the potential to depict polyps with high sensitivity and an acceptable false-positive rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Arbabshirani, M. R., Fornwalt, B. K., Mongelluzzo, G. J., Suever, J. D., Geise, B. D., Patel, A. A., & Moore, G. J. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0015-z · Cited by 443
Johnson, C. D., Harmsen, W. S., Wilson, L. A., Maccarty, R. L., Welch, T. J., Ilstrup, D. M., & Ahlquist, D. A. (2003) · Gastroenterology · doi:10.1016/s0016-5085(03)00894-1 · Cited by 351
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
Metadata
- Authors
- Yoshida, H., Masutani, Y., MacEneaney, P., Rubin, D. T., & Dachman, A. H.
- Venue
- Radiology
- Published
- 2002-02
- Volume
- 222
- Issue
- 2
- Pages
- 327-336
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2132715022
- Cited by
- 243
- References
- 0
- FWCI
- 10.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computerized Detection of Colonic Polyps at CT Colonography on the Basis of Volumetric Features: Pilot Study. https://app.cochat.ai/papers/10.1148/radiol.2222010506
- The paper
- Yoshida, H., Masutani, Y., MacEneaney, P., Rubin, D. T., & Dachman, A. H. (2002). Computerized Detection of Colonic Polyps at CT Colonography on the Basis of Volumetric Features: Pilot Study. Radiology. https://doi.org/10.1148/radiol.2222010506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.