Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record.

Uterine Artery Embolization in Sheep: Comparison of Acute Effects with Polyvinyl Alcohol Particles and Calibrated Microspheres

Pelage, Jean-Pierre, Laurent, Alexandre, Wassef, Michel, Bonneau, Michel, Germain, Delphine, Rymer, Roland, Flaud, Patrice, Martal, Jacques, Merland, Jean-Jacques·2002·Radiology

Abstract

PURPOSE: To compare the effects on the myometrium of polyvinyl alcohol (PVA) particles and calibrated microspheres (MS) in embolization of the uterine arteries in sheep. MATERIALS AND METHODS: Superselective and bilateral embolization of the uterine arteries was performed with PVA particles and calibrated MS within 24 hours after artificial ovulation in 26 adult nonpregnant sheep. PVA particles of four diameters, 150-250, 250-400, 400-600, and 600-1,000 microm, were compared with calibrated MS of similar diameters, 100-300, 300-500, 500-700, and 700-900 microm, in eight groups of sheep. Evaluation was based on histopathologic study of uterus, ovaries, and vascular pedicles after sacrifice 5 days after embolization. The scores of necrosis, the diameter of occluded arteries, and the number of particles were determined. The scores of uterine necrosis were compared by using nonparametric tests (Mann-Whitney U and Kruskal-Wallis). Spearman rank test was used for correlations. RESULTS: PVA particles clumped more readily than did MS. Small particles had a higher score (P =.02) of uterine necrosis than did large particles. PVA particles produced more necrosis than did MS. Size of MS and diameter of occluded arteries showed significant correlation (rho = 0.762, P <.001). Size of PVA particles and diameter of occluded arteries showed no correlation. PVA particles occluded vessels of a wider range of size than did calibrated MS. CONCLUSION: PVA particles are associated with intense uterine necrosis and extensive arterial occlusion regardless of size. Calibrated MS, which are associated with less uterine necrosis, permit a segmental arterial occlusion correlated with size.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2242010847

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Pelage, J.-P., Laurent, A., Wassef, M., Bonneau, M., Germain, D., Rymer, R., Flaud, P., Martal, J., & Merland, J.-J.
Venue
Radiology
Published
2002-08
Volume
224
Issue
2
Pages
436-445
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2094834752
Cited by
166
References
0
FWCI
14.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Uterine Artery Embolization in Sheep: Comparison of Acute Effects with Polyvinyl Alcohol Particles and Calibrated Microspheres. https://app.cochat.ai/papers/10.1148/radiol.2242010847
The paper
Pelage, J.-P., Laurent, A., Wassef, M., Bonneau, M., Germain, D., Rymer, R., Flaud, P., Martal, J., & Merland, J.-J. (2002). Uterine Artery Embolization in Sheep: Comparison of Acute Effects with Polyvinyl Alcohol Particles and Calibrated Microspheres. Radiology. https://doi.org/10.1148/radiol.2242010847

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.