The DOI matches its Crossref record.
Uterine Artery Embolization in Sheep: Comparison of Acute Effects with Polyvinyl Alcohol Particles and Calibrated Microspheres
Abstract
PURPOSE: To compare the effects on the myometrium of polyvinyl alcohol (PVA) particles and calibrated microspheres (MS) in embolization of the uterine arteries in sheep. MATERIALS AND METHODS: Superselective and bilateral embolization of the uterine arteries was performed with PVA particles and calibrated MS within 24 hours after artificial ovulation in 26 adult nonpregnant sheep. PVA particles of four diameters, 150-250, 250-400, 400-600, and 600-1,000 microm, were compared with calibrated MS of similar diameters, 100-300, 300-500, 500-700, and 700-900 microm, in eight groups of sheep. Evaluation was based on histopathologic study of uterus, ovaries, and vascular pedicles after sacrifice 5 days after embolization. The scores of necrosis, the diameter of occluded arteries, and the number of particles were determined. The scores of uterine necrosis were compared by using nonparametric tests (Mann-Whitney U and Kruskal-Wallis). Spearman rank test was used for correlations. RESULTS: PVA particles clumped more readily than did MS. Small particles had a higher score (P =.02) of uterine necrosis than did large particles. PVA particles produced more necrosis than did MS. Size of MS and diameter of occluded arteries showed significant correlation (rho = 0.762, P <.001). Size of PVA particles and diameter of occluded arteries showed no correlation. PVA particles occluded vessels of a wider range of size than did calibrated MS. CONCLUSION: PVA particles are associated with intense uterine necrosis and extensive arterial occlusion regardless of size. Calibrated MS, which are associated with less uterine necrosis, permit a segmental arterial occlusion correlated with size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in Biomaterials and Technologies for Vascular Embolization
Hu, J., Albadawi, H., Chong, B. W., Deipolyi, A. R., Sheth, R. A., Khademhosseini, A., & Oklu, R. (2019) · Advanced Materials · doi:10.1002/adma.201901071 · Cited by 321
Fertility and pregnancy following pelvic arterial embolisation for postpartum haemorrhage
Sentilhes, L., Gromez, A., Clavier, E., Resch, B., Verspyck, E., & Marpeau, L. (2010) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2009.02381.x · Cited by 110
Metadata
- Authors
- Pelage, J.-P., Laurent, A., Wassef, M., Bonneau, M., Germain, D., Rymer, R., Flaud, P., Martal, J., & Merland, J.-J.
- Venue
- Radiology
- Published
- 2002-08
- Volume
- 224
- Issue
- 2
- Pages
- 436-445
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2094834752
- Cited by
- 166
- References
- 0
- FWCI
- 14.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Uterine Artery Embolization in Sheep: Comparison of Acute Effects with Polyvinyl Alcohol Particles and Calibrated Microspheres. https://app.cochat.ai/papers/10.1148/radiol.2242010847
- The paper
- Pelage, J.-P., Laurent, A., Wassef, M., Bonneau, M., Germain, D., Rymer, R., Flaud, P., Martal, J., & Merland, J.-J. (2002). Uterine Artery Embolization in Sheep: Comparison of Acute Effects with Polyvinyl Alcohol Particles and Calibrated Microspheres. Radiology. https://doi.org/10.1148/radiol.2242010847
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).