Hemodialysis Arteriovenous Fistula Maturity: US Evaluation

Robbin, Michelle L., Chamberlain, Nathan E., Lockhart, Mark E., Gallichio, Michael H., Young, Carlton J., Deierhoi, Mark H., Allon, Michael·2002·Radiology

Abstract

PURPOSE: To compare various objective ultrasonographic (US) criteria for native arteriovenous fistula (AVF) maturation with subsequent fistula outcomes and clinical evaluation by experienced dialysis nurses. MATERIALS AND METHODS: US fistula evaluation results were analyzed retrospectively in 69 patients within 4 months after AVF placement; adequacy for dialysis was known in 54. Measurements included minimum venous diameter and blood flow rate. Experienced dialysis nurses examined 30 fistulas clinically. Predictors of fistula adequacy were analyzed with univariate and multivariate logistic regression. Mean fistula diameters and blood flow rates were compared by using analysis of variance or unpaired Student t tests. RESULTS: Fistula adequacy for dialysis doubled if the minimum venous diameter was 0.4 cm or greater (89% [24 of 27]) versus less than 0.4 cm (44% [12 of 27]; P <.001). Fistula adequacy for dialysis was nearly doubled if flow volume was 500 mL/min or greater (84% [26 of 31]) versus less than 500 mL/min (43% [nine of 21]; P =.002). Combining venous diameter and flow volume increased fistula adequacy predictive value: minimum venous diameter of 0.4 cm or greater and flow volume of 500 mL/min or greater (95% [19 of 20]) versus neither criterion met (33% [five of 15]; P =.002). Women were less likely to have an adequate fistula diameter of 0.4 cm or greater: 40% (12 of 30) of women versus 69% (27 of 39; P =.015) of men. No significant differences in blood flow or minimum venous diameter were found during 2-4 postoperative months. Experienced dialysis nurses' accuracy in predicting eventual fistula maturity was 80% (24 of 30). CONCLUSION: US measurements of AVF at 2-4 months in patients undergoing hemodialysis are highly predictive of fistula maturation and adequacy for dialysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2251011367

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 483

Metadata

Authors
Robbin, M. L., Chamberlain, N. E., Lockhart, M. E., Gallichio, M. H., Young, C. J., Deierhoi, M. H., & Allon, M.
Venue
Radiology
Published
2002-10
Volume
225
Issue
1
Pages
59-64
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2027731642
Cited by
483
References
13
FWCI
12.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemodialysis Arteriovenous Fistula Maturity: US Evaluation. https://app.cochat.ai/papers/10.1148/radiol.2251011367
The paper
Robbin, M. L., Chamberlain, N. E., Lockhart, M. E., Gallichio, M. H., Young, C. J., Deierhoi, M. H., & Allon, M. (2002). Hemodialysis Arteriovenous Fistula Maturity: US Evaluation. Radiology. https://doi.org/10.1148/radiol.2251011367

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.