Lung Cancers Missed at Low-Dose Helical CT Screening in a General Population: Comparison of Clinical, Histopathologic, and Imaging Findings
The DOI matches its Crossref record.
Abstract
PURPOSE: To compare clinical, histopathologic, and imaging features of lung cancers missed at low-radiation-dose helical computed tomography (CT). MATERIALS AND METHODS: Eighty-three primary lung cancers were found during an annual low-dose CT screening program and confirmed histopathologically at either surgery or biopsy. Thirty-two of these lung cancers were missed on 39 CT scans: on 23 scans owing to detection errors and on 16 owing to interpretation errors. The clinical characteristics, CT features, and histopathologic findings of these missed lung cancers were correlated. RESULTS: All missed cancers were intrapulmonary, and 28 (88%) were stage IA. All 20 detection errors occurred in cases of adenocarcinoma, 17 (85%) of which were well-differentiated tumors and 11 (55%) of which were in nonsmoking women. The mean size of cancers missed owing to detection error, 9.8 mm, was smaller than that of cancers missed owing to interpretation error, 15.9 mm (P <.001). In the detection error group, the percentages of nodules with ground-glass opacity (91%) or judged to be subtle (91%) were greater than those of nodules in the interpretation error group (38% and 25%, respectively) (P <.001). In the detection error group, 83% (19/23) of cancers were overlapped with, obscured by, or similar in appearance to normal structures such as pulmonary vessels. On 14 of the 16 CT scans with which there were interpretation errors, the CT findings mimicked benign disease, and the patients also had underlying lung disease, such as tuberculosis, emphysema, or lung fibrosis. CONCLUSION: The lung cancers missed at low-dose CT screening in this series generally were very subtle and appeared as small faint nodules, overlapping normal structures, or opacities in a complex background of other disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Self-citationBreast Cancer, Version 4.2017, NCCN Clinical Practice Guidelines in Oncology
Gradishar, W. J., Anderson, B. O., Balassanian, R., Blair, S. L., Burstein, H. J., Cyr, A., Elias, A. D., Farrar, W. B., Forero, A., Giordano, S. H., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0012 · Cited by 1,609
Techniques and Applications of Automatic Tube Current Modulation for CT
Kalra, M. K., Maher, M. M., Toth, T. L., Schmidt, B., Westerman, B. L., Morgan, H. T., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2333031150 · Cited by 725
Lung Cancer Screening, Version 3.2018, NCCN Clinical Practice Guidelines in Oncology
Wood, D. E., Kazerooni, E. A., Baum, S. L., Eapen, G. A., Ettinger, D. S., Hou, L., Jackman, D. M., Klippenstein, D., Kumar, R., Lackner, R. P., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0020 · Cited by 611
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Self-citationLung Image Database Consortium: Developing a Resource for the Medical Imaging Research Community
Armato III, S. G., McLennan, G., McNitt-Gray, M. F., Meyer, C. R., Yankelevitz, D., Aberle, D. R., Henschke, C. I., Hoffman, E. A., Kazerooni, E. A., MacMahon, H., et al. (2004) · Radiology · doi:10.1148/radiol.2323032035 · Cited by 380
Self-citationPark, C. M., Goo, J. M., Lee, H. J., Lee, C. H., Chun, E. J., & Im, J.-G. (2007) · RadioGraphics · doi:10.1148/rg.272065061 · Cited by 294
Doi, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r02 · Cited by 290
Self-citationArmato, S. G., Li, F., Giger, M. L., MacMahon, H., Sone, S., & Doi, K. (2002) · Radiology · doi:10.1148/radiol.2253011376 · Cited by 280
Self-citationComputer-Aided Diagnosis Systems for Lung Cancer: Challenges and Methodologies
El-Baz, A., Beache, G. M., Gimel'farb, G., Suzuki, K., Okada, K., Elnakib, A., Soliman, A., & Abdollahi, B. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/942353 · Cited by 277
Suzuki, K., Armato, S. G., Li, F., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1580485 · Cited by 262
Self-citationRubin, G. D., Lyo, J. K., Paik, D. S., Sherbondy, A. J., Chow, L. C., Leung, A. N., Mindelzun, R., Schraedley-Desmond, P. K., Zinck, S. E., Naidich, D. P., et al. (2005) · Radiology · doi:10.1148/radiol.2341040589 · Cited by 259
Suzuki, K., Li, F., Sone, S., & Doi, K. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852048 · Cited by 219
Self-citationComputer-Aided Diagnosis and Artificial Intelligence in Clinical Imaging
Shiraishi, J., Li, Q., Appelbaum, D., & Doi, K. (2011) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2011.06.004 · Cited by 206
Self-citationSpectrum of diagnostic errors in radiology
Pinto, A. (2010) · World Journal of Radiology · doi:10.4329/wjr.v2.i10.377 · Cited by 202
The past, present and future role of artificial intelligence in imaging
Fazal, M. I., Patel, M. E., Tye, J., & Gupta, Y. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.06.020 · Cited by 179
Gao, J., 1 College of Information Engineering, S. M. U., Jiang, Q., Zhou, B., Chen, D., & 2 Shanghai University of Medicine & Health Science, S. 2. (2019) · Mathematical Biosciences and Engineering · doi:10.3934/mbe.2019326 · Cited by 171
Kakinuma, R., Ohmatsu, H., Kaneko, M., Kusumoto, M., Yoshida, J., Nagai, K., Nishiwaki, Y., Kobayashi, T., Tsuchiya, R., Nishiyama, H., et al. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200401000-00003 · Cited by 163
Low-Dose CT Screening for Lung Cancer: Computer-aided Detection of Missed Lung Cancers
Liang, M., Tang, W., Xu, D. M., Jirapatnakul, A. C., Reeves, A. P., Henschke, C. I., & Yankelevitz, D. (2016) · Radiology · doi:10.1148/radiol.2016150063 · Cited by 154
Metadata
- Authors
- Li, F., Sone, S., Abe, H., MacMahon, H., Armato, S. G., & Doi, K.
- Venue
- Radiology
- Published
- 2002-12
- Volume
- 225
- Issue
- 3
- Pages
- 673-683
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2002774010
- Cited by
- 201
- References
- 0
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.