Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 269

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

CT Evaluation of Bone Dehiscence of the Superior Semicircular Canal as a Cause of Sound- and/or Pressure-induced Vertigo

Belden, Clifford J., Weg, Noah, Minor, Lloyd B., Zinreich, S. James · 2003 · Radiology

Abstract

PURPOSE: To describe the computed tomographic (CT) findings at different collimation widths associated with superior semicircular canal (SSC) dehiscence syndrome and to determine the frequency of these findings in a control population. MATERIALS AND METHODS: Temporal bone CT scans with 1.0-mm and/or 0.5-mm collimation were obtained in 50 patients with sound- and/or pressure-induced vestibular symptoms. The control population consisted of 50 patients undergoing CT at 1.0-mm collimation and 57 patients undergoing CT at 0.5-mm collimation for other reasons. RESULTS: SSC dehiscence was documented on CT scans in all 36 patients with the clinical syndrome, with bilateral findings in six patients. Six other patients without specific clinical signs appeared to have dehiscence on 1.0-mm-collimated scans. Intact bone overlaying the SSC was subsequently identified with 0.5-mm-collimated CT in each case. On the 1.0-mm-collimated scans in 50 control patients, an area judged as possible or definite dehiscence was identified in 18 of 100 ears. The bone overlaying the SSC was intact in each of the 114 control ears evaluated with 0.5-mm-collimated CT. CT findings from the patients with vestibular symptoms combined with those in the control population indicated that the positive predictive value of an apparent dehiscence in the diagnosis of SSC dehiscence syndrome improved from 50% with 1.0-mm-collimated CT with transverse and coronal images to 93% with 0.5-mm-collimated CT with reformation in the plane of the SSC. CONCLUSION: The positive predictive value of CT in identification of SSC dehiscence syndrome improves with 0.5-mm-collimated helical CT and reformation in the SSC plane.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2262010897

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 269

Metadata

Authors
Belden, C. J., Weg, N., Minor, L. B., & Zinreich, S. J.
Venue
Radiology
Published
2003-02
Volume
226
Issue
2
Pages
337-343
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2124107382
Cited by
269
References
16
FWCI
5.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CT Evaluation of Bone Dehiscence of the Superior Semicircular Canal as a Cause of Sound- and/or Pressure-induced Vertigo. https://app.cochat.ai/papers/10.1148/radiol.2262010897
The paper
Belden, C. J., Weg, N., Minor, L. B., & Zinreich, S. J. (2003). CT Evaluation of Bone Dehiscence of the Superior Semicircular Canal as a Cause of Sound- and/or Pressure-induced Vertigo. Radiology. https://doi.org/10.1148/radiol.2262010897

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.