Thoracolumbar Spine Fractures in Patients Who Have Sustained Severe Trauma: Depiction with Multi–Detector Row CT
The DOI matches its Crossref record.
Abstract
PURPOSE: To determine if multi-detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi-detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another's reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi-detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi-detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi-detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi-detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi-detector row CT, respectively, were 145 and 880 US dollars per patient. CONCLUSION: Multi-detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Trauma of the spine and spinal cord: imaging strategies
Parizel, P. M., van der Zijden, T., Gaudino, S., Spaepen, M., Voormolen, M. H. J., Venstermans, C., De Belder, F., van den Hauwe, L., & Van Goethem, J. (2010) · European Spine Journal · doi:10.1007/s00586-009-1123-5 · Cited by 182
“Recent literature data indicate that MDCT diagnoses thoracolumbar spine fractures more accurately than plain X-ray films [31, 32].”
BackgroundDetection of osteoporotic vertebral fractures using multidetector CT
Bauer, J. S., Müller, D., Ambekar, A., Dobritz, M., Matsuura, M., Eckstein, F., Rummeny, E. J., & Link, T. M. (2006) · Osteoporosis International · doi:10.1007/s00198-005-0023-8 · Cited by 66
“Wintermark et al. [ 22 ] and Brandt et al. [14] came to the same conclusion in their studies in 2003 and 2004, respectively.”
ResultCabitza, F., Famiglini, L., Fregosi, C., Pe, S., Parimbelli, E., La Maida, G. A., & Gallazzi, E. (2025) · Proceedings of the 30th International Conference on Intelligent User Interfaces · doi:10.1145/3708359.3712157 · Cited by 11
“Detecting traumatic Thoraco-Lumbar (TL) fractures from vertebral X-rays is a highly complex medical task with still a significant error rate [55], where missed diagnoses can strongly impact patient outcomes.”
Metadata
- Authors
- Wintermark, M., Mouhsine, E., Theumann, N., Mordasini, P., van Melle, G., Leyvraz, P. F., & Schnyder, P.
- Venue
- Radiology
- Published
- 2003-06
- Volume
- 227
- Issue
- 3
- Pages
- 681-689
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2119415170
- Cited by
- 191
- References
- 0
- FWCI
- 10.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.