CT-guided Transthoracic Needle Aspiration Biopsy of Pulmonary Nodules: Needle Size and Pneumothorax Rate
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the effect of coaxial needle size on pneumothorax rate and the diagnostic accuracy of computed tomography (CT)-guided transthoracic needle aspiration biopsy (TNAB) of pulmonary nodules. MATERIALS AND METHODS: Retrospective review of 846 consecutive CT-guided TNAB procedures was performed. A coaxial approach was implemented in all patients by using an 18- or 19-gauge outer stabilizing needle through which a smaller aspiration needle or automated biopsy gun was inserted for tissue sampling. Univariate and multivariate regression analyses were used to analyze coaxial needle size, age, sex, smoking history, lesion size, use of an automated core biopsy gun, number of needle passes, and frequency of chest tube placement. Sensitivity, specificity, and diagnostic accuracy were calculated for 676 patients with at least 18 months of clinical follow-up. RESULTS: Pneumothorax occurred in 226 of 846 patients. Coaxial needle size and patient age had a significant effect on pneumothorax rate. Pneumothorax occurred in 124 (38%) of 324 patients who underwent procedures with 18-gauge needles and in 121 (23%) of 522 patients who underwent procedures with 19-gauge needles (P <.001). The overall diagnostic accuracy was 96% for procedures performed with 18-gauge needles and 92% for procedures performed with 19-gauge needles, with a sensitivity of 95% and 89% and a specificity of 100% and 99%, respectively. Pneumothorax occurred in 153 patients older than 60 years, in 99 patients 60 years and younger (P <.02), in 90 patients older than 70 years, and in 162 patients younger than 70 years (P <.01). The relationship between pneumothorax rate and age as a continuous distribution was not significant (P <.07), nor were the 50- or 75-year age cutoffs (P <.06 and P <.9, respectively). CONCLUSION: Use of a smaller coaxial stabilizing needle produces a substantially decreased risk of pneumothorax with comparable diagnostic accuracy, sensitivity, and specificity for histopathologic diagnosis of pulmonary nodules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Percutaneous transthoracic needle biopsy.
Westcott, J. L. (1988) · Radiology · doi:10.1148/radiology.169.3.3055026 · Cited by 275
Percutaneous Transthoracic Needle Aspiration Biopsy
Larscheid, R. C., Thorpe, P. E., & Scott, W. J. (1998) · CHEST Journal · doi:10.1378/chest.114.3.704 · Cited by 172
Predicting Risk of Pneumothorax in Needle Biopsy of the Lung
Poe, R. H., Kallay, M. C., Wicks, C. M., & Odoroff, C. L. (1984) · CHEST Journal · doi:10.1378/chest.85.2.232 · Cited by 112
Catheter Aspiration for Simple Pneumothorax: Experience With 114 Patients
Delius, R. E. (1989) · Archives of Surgery · doi:10.1001/archsurg.1989.01410070091018 · Cited by 70
Risk of Pneumothorax Not Increased by Obstructive Lung Disease in Percutaneous Needle Biopsy
Anderson, C. L. V., Crespo, J. C. A., & Lie, T. H. (1994) · CHEST Journal · doi:10.1378/chest.105.6.1705 · Cited by 60
Cited by
Establishing the Diagnosis of Lung Cancer
Rivera, M. P., Mehta, A. C., & Wahidi, M. M. (2013) · Chest · doi:10.1378/chest.12-2353 · Cited by 1,089
Wiener, R. S., Schwartz, L. M., Woloshin, S., & Welch, H. G. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-3-201108020-00003 · Cited by 503
Initial Diagnosis of Lung Cancer
Rivera, M. P., & Mehta, A. C. (2007) · Chest · doi:10.1378/chest.07-1357 · Cited by 422
Quality Improvement Guidelines for Percutaneous Needle Biopsy
Gupta, S., Wallace, M. J., Cardella, J. F., Kundu, S., Miller, D. L., & Rose, S. C. (2010) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2010.01.011 · Cited by 345
Gex, G., Pralong, J. A., Combescure, C., Seijo, L., Rochat, T., & Soccal, P. M. (2014) · Respiration · doi:10.1159/000355710 · Cited by 290
Metadata
- Authors
- Geraghty, P. R., Kee, S. T., McFarlane, G., Razavi, M. K., Sze, D. Y., & Dake, M. D.
- Venue
- Radiology
- Published
- 2003-11
- Volume
- 229
- Issue
- 2
- Pages
- 475-481
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2161115828
- Cited by
- 441
- References
- 5
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.