Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record.

Evaluation of Patients after Coronary Artery Bypass Surgery: CT Angiographic Assessment of Grafts and Coronary Arteries

Nieman, Koen, Pattynama, Peter M. T., Rensing, Benno J., van Geuns, Robert-Jan M., de Feyter, Pim J. · 2003 · Radiology

Abstract

PURPOSE: To evaluate the accuracy of electrocardiography (ECG)-gated multi-detector row computed tomography (CT) in enabling the detection of obstruction of both bypass grafts and coronary arteries in symptomatic patients who have undergone coronary artery bypass grafting. MATERIALS AND METHODS: ECG-gated contrast material-enhanced multi-detector row CT angiography was performed in 24 patients after bypass surgery. Two independent blinded observers evaluated all graft and coronary segments (> or =2.0-mm diameter) for occlusion and stenosis (50%-99% luminal reduction). Conventional angiography was regarded as the standard of reference. Descriptive parameters were calculated, and the results for arterial grafts, venous grafts, and coronary arteries, as well as for high and low heart rates, were compared by using a two-sided Fisher exact test. RESULTS: The following results were obtained by observers 1 and 2, respectively: Of the 60 venous graft segments, 60 (100%) and 57 (95.0%) were assessable, with an overall detection of all 17 occlusions (both observers) and three (50.0%) and five (83.3%) of six stenoses. Of 26 arterial graft segments, 19 (73.1%) and 15 (57.7%) were assessable. In the assessable segments, four of four (100%) and two of three (66.7%) stenoses and occlusions were detected, while one and two obstructions were located in nonassessable segments. Of 211 coronary segments, 146 (69.2%) and 140 (66.4%) were assessable, and detection of 50%-100% obstruction yielded a sensitivity of 89.9% (71 of 79) and 79.4% (54 of 68) and a specificity of 74.6% (50 of 67) and 72.2% (52 of 72) for each observer. Unlike the assessment of venous and arterial grafts, assessment of the coronary arteries with multi-detector row CT was significantly better in patients with low heart rates (P <.01). CONCLUSION: Multi-detector row CT allows noninvasive angiographic evaluation of both coronary arteries and bypass grafts in patients who have undergone bypass surgery. Multi-detector row CT is more effective in examining venous grafts compared with arterial grafts and diffusely diseased coronary arteries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2293020856

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Nieman, K., Pattynama, P. M. T., Rensing, B. J., van Geuns, R.-J. M., & de Feyter, P. J.
Venue
Radiology
Published
2003-12
Volume
229
Issue
3
Pages
749-756
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2049024473
Cited by
200
References
0
FWCI
20.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Patients after Coronary Artery Bypass Surgery: CT Angiographic Assessment of Grafts and Coronary Arteries. https://app.cochat.ai/papers/10.1148/radiol.2293020856
The paper
Nieman, K., Pattynama, P. M. T., Rensing, B. J., van Geuns, R.-J. M., & de Feyter, P. J. (2003). Evaluation of Patients after Coronary Artery Bypass Surgery: CT Angiographic Assessment of Grafts and Coronary Arteries. Radiology. https://doi.org/10.1148/radiol.2293020856

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.