Evaluation of Patients after Coronary Artery Bypass Surgery: CT Angiographic Assessment of Grafts and Coronary Arteries
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the accuracy of electrocardiography (ECG)-gated multi-detector row computed tomography (CT) in enabling the detection of obstruction of both bypass grafts and coronary arteries in symptomatic patients who have undergone coronary artery bypass grafting. MATERIALS AND METHODS: ECG-gated contrast material-enhanced multi-detector row CT angiography was performed in 24 patients after bypass surgery. Two independent blinded observers evaluated all graft and coronary segments (> or =2.0-mm diameter) for occlusion and stenosis (50%-99% luminal reduction). Conventional angiography was regarded as the standard of reference. Descriptive parameters were calculated, and the results for arterial grafts, venous grafts, and coronary arteries, as well as for high and low heart rates, were compared by using a two-sided Fisher exact test. RESULTS: The following results were obtained by observers 1 and 2, respectively: Of the 60 venous graft segments, 60 (100%) and 57 (95.0%) were assessable, with an overall detection of all 17 occlusions (both observers) and three (50.0%) and five (83.3%) of six stenoses. Of 26 arterial graft segments, 19 (73.1%) and 15 (57.7%) were assessable. In the assessable segments, four of four (100%) and two of three (66.7%) stenoses and occlusions were detected, while one and two obstructions were located in nonassessable segments. Of 211 coronary segments, 146 (69.2%) and 140 (66.4%) were assessable, and detection of 50%-100% obstruction yielded a sensitivity of 89.9% (71 of 79) and 79.4% (54 of 68) and a specificity of 74.6% (50 of 67) and 72.2% (52 of 72) for each observer. Unlike the assessment of venous and arterial grafts, assessment of the coronary arteries with multi-detector row CT was significantly better in patients with low heart rates (P <.01). CONCLUSION: Multi-detector row CT allows noninvasive angiographic evaluation of both coronary arteries and bypass grafts in patients who have undergone bypass surgery. Multi-detector row CT is more effective in examining venous grafts compared with arterial grafts and diffusely diseased coronary arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Fitzgibbon, G. M., Kafka, H. P., Leach, A. J., Keon, W. J., Hooper, G. D., & Burton, J. R. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00206-9 · Cited by 1,347
Achenbach, S., Giesler, T., Ropers, D., Ulzheimer, S., Derlien, H., Schulte, C., Wenkel, E., Moshage, W., Bautz, W., Daniel, W. G., et al. (2001) · Circulation · doi:10.1161/01.cir.103.21.2535 · Cited by 667
Ohnesorge, B., Flohr, T., Becker, C., Kopp, A. F., Schoepf, U. J., Baum, U., Knez, A., Klingenbeck-Regn, K., & Reiser, M. F. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv30564 · Cited by 516
Techniques for the Detection of Coronary Atherosclerosis: Multi–detector Row CT Coronary Angiography
Vogl, T. J., Abolmaali, N. D., Diebold, T., Engelmann, K., Ay, M., Dogan, S., Wimmer-Greinecker, G., Moritz, A., & Herzog, C. (2002) · Radiology · doi:10.1148/radiol.2231010515 · Cited by 203
Recurrence of angina after coronary artery bypass surgery: Predictors and prognosis (CASS registry)
Cameron, A., Davis, K. B., & Rogers, W. J. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00280-4 · Cited by 149
Stanford, W. L., Brundage, B. H., MacMillan, R. M., Chomka, E. V., Bateman, T. M., Eldredge, W. J., Lipton, M. J., White, C. W., Wilson, R. F., Johnson, M. R., et al. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90348-8 · Cited by 83
Ha, J., Cho, S. Y., Shim, W., Chung, N., Jang, Y., Lee, H. M., Choe, K. O., Chung, W., Choi, S. H., Yoo, K. J., et al. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.172.4.10587146 · Cited by 52
Bateman, T. M., Gray, R. J., Whiting, J. S., Sethna, D. H., Berman, D. S., Matloff, J. M., Swan, H. J. C., & Forrester, J. S. (1987) · Circulation · doi:10.1161/01.cir.75.5.1018 · Cited by 42
Cine computed tomographic evaluation of aortocoronary bypass graft patency
Bateman, T. M., Gray, R. J., Whiting, J. S., Matloff, J. M., Berman, D. S., & Forrester, J. S. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80202-9 · Cited by 34
Cited by
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Schroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Self-citationBluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Schuijf, J. D., Bax, J. J., Shaw, L. J., de Roos, A., Lamb, H. J., van der Wall, E. E., & Wijns, W. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.03.022 · Cited by 255
Ropers, D., Pohle, F.-K., Kuettner, A., Pflederer, T., Anders, K., Daniel, W. G., Bautz, W., Baum, U., & Achenbach, S. (2006) · Circulation · doi:10.1161/circulationaha.106.631051 · Cited by 253
Metadata
- Authors
- Nieman, K., Pattynama, P. M. T., Rensing, B. J., van Geuns, R.-J. M., & de Feyter, P. J.
- Venue
- Radiology
- Published
- 2003-12
- Volume
- 229
- Issue
- 3
- Pages
- 749-756
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2049024473
- Cited by
- 200
- References
- 10
- FWCI
- 20.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.