Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diagnosis of Acute Pulmonary Embolism in Outpatients: Comparison of Thin-Collimation Multi–Detector Row Spiral CT and Planar Ventilation-Perfusion Scintigraphy

Coche, Emmanuel, Verschuren, Franck, Keyeux, André, Goffette, Pierre, Goncette, Louis, Hainaut, Philippe, Hammer, Frank, Lavenne, Edith, Zech, Francis, Meert, Philippe, Reynaert, Marc S. · 2003 · Radiology

Abstract

PURPOSE: To compare multi-detector row computed tomography (CT) and ventilation-perfusion (V-P) scintigraphy in the diagnosis of acute pulmonary embolism (PE) in outpatients who were cared for in the emergency department. MATERIALS AND METHODS: Ninety-four nonconsecutive patients, in whom acute PE was suspected, underwent thin-collimation multi-detector row CT (collimation, 4 x 1 mm; pitch, 1.25; scanning time, 0.5 second) and V-P scintigraphy. Concordance between CT and scintigraphic images was used in the diagnosis of PE. Pulmonary angiography was performed within 24 hours if interpretations of V-P and spiral CT images were inconclusive or discordant. Sensitivity and specificity values were calculated for V-P scintigrams and CT scans of the lungs. The rates of conclusive results for scintigraphy and CT were compared. RESULTS: The sensitivity of thin-collimation multi-detector row CT and V-P scintigraphy for the detection of PE was 96% (27 of 28; CI: 82%, 99%) and 98% (65 of 66; CI: 92%, 99%), respectively. The specificity of CT and V-P scintigraphy was 86% (24 of 28; CI: 67%, 96%) and 88% (58 of 66; CI: 77%, 94%), respectively. Seven V-P scintigrams were of intermediate probability, and one spiral CT study was indeterminate. Examinations with spiral CT yielded conclusive results more often than examinations with planar V-P scintigraphy (P <.05). Five V-P scintigrams and spiral CT scans were discordant. Twelve pulmonary angiographic examinations were performed. Angiographic findings were concordant in 10 (91%) of 11 patients with conclusive CT scans in whom pulmonary angiography was attempted. CT was used to establish an alternative diagnosis in 19 (29%) of 66 patients in whom PE was excluded. CONCLUSION: Thin-collimation multi-detector row CT is more accurate than V-P scintigraphy in the diagnosis of acute PE in outpatients. Furthermore, CT provides alternative diagnoses for patients without PE on high-quality transverse or near-isotropic reformatted images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2293020889

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Coche, E., Verschuren, F., Keyeux, A., Goffette, P., Goncette, L., Hainaut, P., Hammer, F., Lavenne, E., Zech, F., Meert, P., & Reynaert, M. S.
Venue
Radiology
Published
2003-12
Volume
229
Issue
3
Pages
757-765
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2053666667
Cited by
160
References
1
FWCI
6.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis of Acute Pulmonary Embolism in Outpatients: Comparison of Thin-Collimation Multi–Detector Row Spiral CT and Planar Ventilation-Perfusion Scintigraphy. https://app.cochat.ai/papers/10.1148/radiol.2293020889
The paper
Coche, E., Verschuren, F., Keyeux, A., Goffette, P., Goncette, L., Hainaut, P., Hammer, F., Lavenne, E., Zech, F., Meert, P., & Reynaert, M. S. (2003). Diagnosis of Acute Pulmonary Embolism in Outpatients: Comparison of Thin-Collimation Multi–Detector Row Spiral CT and Planar Ventilation-Perfusion Scintigraphy. Radiology. https://doi.org/10.1148/radiol.2293020889

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.