The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Thyroid Tissue: US-guided Percutaneous Laser Thermal Ablation
Abstract
PURPOSE: To evaluate in vivo the safety and effectiveness of percutaneous laser thermal ablation (LTA) in the debulking of thyroid lesions. MATERIALS AND METHODS: Twenty-five adult patients at poor surgical risk with cold nodules (n = 8), autonomously hyperfunctioning thyroid nodules (n = 16), or anaplastic carcinoma (n = 1) underwent LTA. One to four 21-gauge spinal needles were inserted with ultrasonographic (US) guidance into the thyroid lesions. A 300-microm-diameter quartz optical fiber was advanced through the sheath of the needle. Nd:YAG laser was used with output power of 3-5 W. Side effects, complications, and clinical and hormonal changes were evaluated at the end of LTA and during follow-up. Linear regression analysis was used to investigate the correlation between energy delivered and reduction in nodule volume. Volume of induced necrosis and reduction in nodule volume were assessed with US or computed tomography. RESULTS: LTA was performed without difficulties in 76 LTA sessions. After treatment with 5 W, two patients experienced mild dysphonia, which resolved after 48 hours and 2 months. Improvement of local compression symptoms was experienced by 12 of 14 (86%) patients. Thyroid-stimulating hormone (TSH) was detectable in five of 16 (31%) patients with hyperfunctioning nodules at 6 months after LTA. Volume of induced necrosis ranged from 0.8 to 3.9 mL per session. Anaplastic carcinoma treated with four fibers yielded 32.0 mL of necrosis. Echo structure and baseline volume did not influence response. Energy load and reduction in nodule volume were significantly correlated (r(2) =.75, P <.001). Mean nodule volume reduction at 6 months in hyperfunctioning nodules was 3.3 mL +/- 2.8 (62% +/- 21.4 [SD]) and in cold nodules was 7.7 mL +/- 7.5 (63% +/- 13.8). CONCLUSION: LTA may be a therapeutic tool for highly selected problems in the treatment of thyroid lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monzani, F., Caraccio, N., Goletti, O., Lippolis, P. V., Casolaro, A., Del Guerra, P., Cavina, E., & Miccoli, P. (1997) · Clinical Endocrinology · doi:10.1046/j.1365-2265.1997.d01-1752.x · Cited by 112
Zingrillo, M., Torlontano, M., Ghiggi, M. R., Frusciante, V., Varraso, A., Liuzzi, A., & Trischitta, V. (2000) · Thyroid · doi:10.1089/thy.2000.10.985 · Cited by 54
Cited by
Radiofrequency ablation of benign thyroid nodules: safety and imaging follow-up in 236 patients
Jeong, W. K., Baek, J. H., Rhim, H., Kim, Y. S., Kwak, M. S., Jeong, H. J., & Lee, D. (2008) · European Radiology · doi:10.1007/s00330-008-0880-6 · Cited by 473
Spiezia, S., Garberoglio, R., Milone, F., Ramundo, V., Caiazzo, C., Assanti, A. P., Deandrea, M., Limone, P. P., Macchia, P. E., Lombardi, G., et al. (2009) · Thyroid · doi:10.1089/thy.2008.0202 · Cited by 277
Self-citationRadiofrequency Ablation for Autonomously Functioning Thyroid Nodules: A Multicenter Study
Sung, J. Y., Baek, J. H., Jung, S. L., Kim, J.-H., Kim, K. S., Lee, D., Kim, W. B., & Na, D. G. (2015) · Thyroid · doi:10.1089/thy.2014.0100 · Cited by 154
Metadata
- Authors
- Pacella, C. M., Bizzarri, G., Spiezia, S., Bianchini, A., Guglielmi, R., Crescenzi, A., Pacella, S., Toscano, V., & Papini, E.
- Venue
- Radiology
- Published
- 2004-07
- Volume
- 232
- Issue
- 1
- Pages
- 272-280
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2146431570
- Cited by
- 192
- References
- 2
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thyroid Tissue: US-guided Percutaneous Laser Thermal Ablation. https://app.cochat.ai/papers/10.1148/radiol.2321021368
- The paper
- Pacella, C. M., Bizzarri, G., Spiezia, S., Bianchini, A., Guglielmi, R., Crescenzi, A., Pacella, S., Toscano, V., & Papini, E. (2004). Thyroid Tissue: US-guided Percutaneous Laser Thermal Ablation. Radiology. https://doi.org/10.1148/radiol.2321021368
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.