Organizing Pneumonia: Perilobular Pattern at Thin-Section CT
The DOI matches its Crossref record.
Abstract
PURPOSE: To describe the appearance and frequency of a perilobular pattern at thin-section computed tomography (CT) in patients with organizing pneumonia. MATERIALS AND METHODS: Thin-section CT scans of 21 consecutive patients with cryptogenic organizing pneumonia were retrospectively reviewed. Two thoracic radiologists in consensus recorded the presence and distribution of the CT abnormalities (consolidation, ground-glass opacification, nodules, bandlike opacities, interlobular septal thickening, and findings of fibrosis), with a particular focus on the presence and predominant location of the perilobular pattern, that is, a poorly defined arcadelike or polygonal appearance. RESULTS: The perilobular pattern was present in 12 (57%) of 21 patients, 10 of whom had five or more perilobular opacities. Other CT features were consolidation (20 patients, 95%), which was predominantly a subpleural and/or peribronchial distribution in 17 patients, and ground-glass opacification (18 patients, 86%). Bandlike opacities and interlobular septal thickening were observed in four patients and one patient, respectively. The perilobular pattern abutted the pleural surface in 10 of 12 patients and was surrounded by aerated lung parenchyma in 11 of 12 patients. There was no obvious relationship between perilobular opacities and CT findings indicative of established fibrosis. CONCLUSION: A perilobular pattern was present in more than half of the patients, along with the expected thin-section CT features of organizing pneumonia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Travis, W. D., Costabel, U., Hansell, D. M., King, T. E., Lynch, D. A., Nicholson, A. G., Ryerson, C. J., Ryu, J. H., Selman, M., Wells, A. U., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201308-1483st · Cited by 4,290
Self-citationFleischner Society: Glossary of Terms for Thoracic Imaging
Hansell, D. M., Bankier, A. A., MacMahon, H., McLoud, T. C., Müller, N. L., & Remy, J. (2008) · Radiology · doi:10.1148/radiol.2462070712 · Cited by 4,198
Self-citationRadiological findings from 81 patients with COVID-19 pneumonia in Wuhan, China: a descriptive study
Shi, H., Han, X., Jiang, N., Cao, Y., Alwalid, O., Gu, J., Fan, Y., & Zheng, C. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30086-4 · Cited by 3,664
Temporal Changes of CT Findings in 90 Patients with COVID-19 Pneumonia: A Longitudinal Study
Wang, Y., Dong, C., Hu, Y., Li, C., Ren, Q., Zhang, X., Shi, H., & Zhou, M. (2020) · Radiology · doi:10.1148/radiol.2020200843 · Cited by 949
Cryptogenic organising pneumonia
Cordier, J.-F. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00013505 · Cited by 519
Persistent Pulmonary Nodular Ground-Glass Opacity at Thin-Section CT: Histopathologic Comparisons
Kim, H. Y., Shim, Y. M., Lee, K. S., Han, J., Yi, C. A., & Kim, Y. K. (2007) · Radiology · doi:10.1148/radiol.2451061682 · Cited by 371
Middle East Respiratory Syndrome Coronavirus (MERS-CoV) Infection: Chest CT Findings
Ajlan, A. M., Ahyad, R. A., Jamjoom, L. G., Alharthy, A., & Madani, T. A. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.14.13021 · Cited by 286
Kligerman, S. J., Franks, T. J., & Galvin, J. R. (2013) · RadioGraphics · doi:10.1148/rg.337130057 · Cited by 218
Metadata
- Authors
- Ujita, M., Renzoni, E. A., Veeraraghavan, S., Wells, A. U., & Hansell, D. M.
- Venue
- Radiology
- Published
- 2004-09
- Volume
- 232
- Issue
- 3
- Pages
- 757-761
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2156696474
- Cited by
- 195
- References
- 0
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.