CoChat

Soft-Tissue Tumors: Value of Static and Dynamic Gadopentetate Dimeglumine–enhanced MR Imaging in Prediction of Malignancy

van Rijswijk, Catharina S. P., Geirnaerdt, Maarje J. A., Hogendoorn, Pancras C. W., Taminiau, Antonie H. M., van Coevorden, Frits, Zwinderman, Aeilko H., Pope, Thomas L., Bloem, Johan L. · 2004 · Radiology
Cited by 218

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: To prospectively evaluate static and dynamic gadopentetate dimeglumine-enhanced magnetic resonance (MR) imaging relative to nonenhanced MR imaging in differentiation of benign from malignant soft-tissue lesions and to evaluate which MR imaging parameters are most predictive of malignancy, with associated interobserver variability. MATERIALS AND METHODS: One hundred forty consecutive patients (78 male patients [median age, 51 years], 62 female patients [median age, 53 years]) with a soft-tissue mass underwent nonenhanced static and dynamic contrast material-enhanced MR imaging. Diagnosis was based on histologic findings in surgical specimens (86 of 140), findings at core-needle biopsy (43 of 140), or results of all imaging procedures with clinical follow-up (11 of 140). Multivariate logistic regression analysis was used to identify the best combination of MR imaging parameters that might be predictive of malignancy. Subjective overall performance of two observers was evaluated with receiver operating characteristic analysis. RESULTS: For subjective overall diagnosis, area under the receiver operating characteristic curve, a measure for diagnostic accuracy, was significantly larger for combined nonenhanced and contrast-enhanced MR imaging than it was for nonenhanced MR imaging alone, with no significant difference between observers. Multivariate analysis of all lesions revealed that combined nonenhanced static and dynamic contrast-enhanced MR imaging parameters were significantly superior to nonenhanced MR imaging parameters alone and to nonenhanced MR imaging parameters combined with static contrast-enhanced MR imaging parameters in prediction of malignancy. The most discriminating parameters were presence of liquefaction, start of dynamic enhancement (time interval between start of arterial and tumor enhancement), and lesion size (diameter). Results for extremity lesions were the same, with one exception: With dynamic contrast-enhanced MR imaging parameters, diagnostic performance of one observer did not improve. CONCLUSION: Static and dynamic contrast-enhanced MR imaging, when added to nonenhanced MR imaging, improved differentiation between benign and malignant soft-tissue lesions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2332031110

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
van Rijswijk, C. S. P., Geirnaerdt, M. J. A., Hogendoorn, P. C. W., Taminiau, A. H. M., van Coevorden, F., Zwinderman, A. H., Pope, T. L., & Bloem, J. L.
Venue
Radiology
Published
2004-11
Volume
233
Issue
2
Pages
493-502
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2111821981
Cited by
218
References
2
FWCI
4.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.