Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Anomalous Coronary Arteries in Adults: Depiction at Multi–Detector Row CT Angiography

Datta, Jaydip, White, Charles S., Gilkeson, Robert C., Meyer, Cristopher A., Kansal, Sarita, Jani, Manish L., Arildsen, Ronald C., Read, Katrina · 2005 · Radiology

Abstract

PURPOSE: To retrospectively determine the imaging features of anomalous coronary arteries depicted at multi-detector row computed tomographic (CT) angiography in 18 patients seen at four institutions. MATERIALS AND METHODS: Eighteen patients underwent imaging with a four- or 16-section multi-detector row CT unit by using retrospective electrocardiographic (ECG) gating after infusion of 120-150 mL of intravenous contrast material. Section thicknesses of 0.8-3.0 mm were achieved during breath holding, and images were reconstructed with a 50% overlap. Volumetric reconstructions were obtained for each patient. Each study was assessed retrospectively for the origin and course of the anomalous coronary artery by two thoracic radiologists; decisions were made in consensus. Institutional review board exemption and informed consent waiver was granted at each institution. The study was compliant with the Health Insurance Portability and Accountability Act. RESULTS: Seventeen patients were referred because of equivocal findings at cardiac catheterization or echocardiography; in one, the anomalous coronary artery was incidental. A total of 20 anomalous vessels were found. Twelve patients with 14 variant vessels had an anomalous origin of a left coronary artery (right cusp, 13; noncoronary cusp, one). In four patients, an anomalous right coronary artery originated from the left side; one patient had a single coronary artery arising from the right cusp. In one patient, a left coronary artery-to-vein fistula was observed. In 10 patients, the anomalous vessel passed between the aorta and the main pulmonary artery or right ventricular outflow track. In each case, the origin of the anomalous coronary artery and its course in relationship to the great vessels were unequivocally demonstrated. Volumetric images were useful for showing the three-dimensional orientation of the anomalous coronary artery with respect to the great vessels and cardiac chambers. CONCLUSION: Multi-detector row CT angiography provided accurate depiction of vessel origin and course in this review of 20 anomalous coronary arteries. The results of this study suggest that CT is a viable noninvasive modality for delineating coronary arterial anomalies, particularly if findings at coronary angiography are equivocal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2353040314

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 241

Metadata

Authors
Datta, J., White, C. S., Gilkeson, R. C., Meyer, C. A., Kansal, S., Jani, M. L., Arildsen, R. C., & Read, K.
Venue
Radiology
Published
2005-06
Volume
235
Issue
3
Pages
812-818
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2004125150
Cited by
241
References
1
FWCI
17.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anomalous Coronary Arteries in Adults: Depiction at Multi–Detector Row CT Angiography. https://app.cochat.ai/papers/10.1148/radiol.2353040314
The paper
Datta, J., White, C. S., Gilkeson, R. C., Meyer, C. A., Kansal, S., Jani, M. L., Arildsen, R. C., & Read, K. (2005). Anomalous Coronary Arteries in Adults: Depiction at Multi–Detector Row CT Angiography. Radiology. https://doi.org/10.1148/radiol.2353040314

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.