Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 263

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Dynamic Bilateral Contrast-enhanced MR Imaging of the Breast: Trade-off between Spatial and Temporal Resolution

Kuhl, Christiane K., Schild, Hans H., Morakkabati, Nuschin · 2005 · Radiology

Abstract

PURPOSE: To investigate prospectively the trade-off between temporal and spatial resolution in dynamic contrast material-enhanced bilateral magnetic resonance (MR) imaging of the breast. MATERIALS AND METHODS: Informed consent and institutional review board approval were obtained. An intraindividual comparative study was performed in 30 patients (mean age, 53 years; age range, 27-70 years) with a total of 54 enhancing lesions (28 benign and 26 malignant) who underwent dynamic MR imaging of the breast twice, once with a standard dynamic protocol (256 x 256 matrix, 69 seconds per acquisition) and once on a separate day with a modified dynamic protocol (400 x 512 matrix, 116 seconds per acquisition). Systematic qualitative analysis of morphologic features and region-of-interest-based analysis of enhancement kinetics were performed. RESULTS: A statistically significant difference (generalized linear modeling) in enhancement rates of benign versus malignant lesions was lost when moving from the standard to the modified dynamic protocol. Kinetic information on signal intensity time course patterns was preserved. Delineation of lesion margins and internal architecture was clearly superior with the modified dynamic protocol, which allowed identification of lesion features associated with high positive predictive value or high negative predictive value for breast cancer. Ten benign lesions classified as Breast Imaging Reporting and Data System (BI-RADS) category 3 with the standard protocol were correctly downgraded to BI-RADS category 2 with the modified protocol owing to visualization of internal septations. Thirteen malignant lesions categorized as BI-RADS category 3 or 4 with the standard protocol were correctly upgraded to BI-RADS category 4 or 5 with the modified protocol owing to visualization of spicules or rim enhancement. Receiver operating characteristic analysis revealed a significantly larger area under the curve for results obtained with the modified dynamic protocol. CONCLUSION: Increased spatial resolution significantly improves diagnostic confidence and accuracy at dynamic MR imaging, even if this improvement occurs at the expense of temporal resolution. Loss of kinetic information regarding enhancement rates proved to be not diagnostically relevant because enhancement rates showed broad overlap between benign and malignant lesions and were therefore of only limited diagnostic use in the individual patient. Kinetic information regarding time course pattern was preserved and confirmed as having high specificity and high positive predictive value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2363040811

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 263

Metadata

Authors
Kuhl, C. K., Schild, H. H., & Morakkabati, N.
Venue
Radiology
Published
2005-09
Volume
236
Issue
3
Pages
789-800
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2044551179
Cited by
263
References
22
FWCI
12.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic Bilateral Contrast-enhanced MR Imaging of the Breast: Trade-off between Spatial and Temporal Resolution. https://app.cochat.ai/papers/10.1148/radiol.2363040811
The paper
Kuhl, C. K., Schild, H. H., & Morakkabati, N. (2005). Dynamic Bilateral Contrast-enhanced MR Imaging of the Breast: Trade-off between Spatial and Temporal Resolution. Radiology. https://doi.org/10.1148/radiol.2363040811

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.