Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 185

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Accuracy of Liver Fat Quantification at MR Imaging: Comparison of Out-of-Phase Gradient-Echo and Fat-saturated Fast Spin-Echo Techniques—Initial Experience

Qayyum, Aliya, Goh, Jeffrey S., Kakar, Sanjay, Yeh, Benjamin M., Merriman, Raphael B., Coakley, Fergus V.·2005·Radiology

Abstract

PURPOSE: To retrospectively determine the relative accuracy of liver fat quantification with out-of-phase gradient-echo magnetic resonance (MR) imaging and fat-saturated fast spin-echo MR imaging in patients with and without cirrhosis, with histologic analysis as the reference standard. MATERIALS AND METHODS: Committee on Human Research approval was obtained. Patient consent was not required. Data collection ended before HIPAA regulations were implemented, but patient anonymity was maintained. Twenty-seven patients, 16 with cirrhosis, were retrospectively identified who underwent MR imaging before histopathologic evaluation of liver fat at biopsy or surgery. The patient population consisted of 15 male and 12 female patients (mean age, 55 years; range, 16-75 years). One radiologist blinded to the histopathologic results recorded mean signal intensity derived from three regions of interest placed in the right and left lobes of the liver on three sections and signal intensity of the spleen from one region of interest within the same section. Liver fat was quantified with the relative loss of signal intensity on out-of-phase images compared with that on in-phase T1-weighted gradient-echo images and with relative loss of signal intensity on T2-weighted fast spin-echo MR images obtained with fat saturation compared with those obtained without fat saturation. Hotelling t test was used to compare correlation coefficients between relative signal intensity differences and histopathologically determined percentage of fat. RESULTS: In patients without cirrhosis, liver fat quantification with fat-saturated fast spin-echo MR imaging was significantly better than it was with out-of-phase gradient-echo MR imaging (r = 0.92 vs 0.69, P < .01). In patients with cirrhosis, liver fat quantification was correlated only with fat-saturated fast spin-echo MR imaging (r = 0.76, P < .01); the relative signal intensity loss on out-of-phase gradient-echo MR images was not correlated with histopathologically determined percentage of fat (r = 0.25, P = .36). CONCLUSION: Preliminary results suggest liver fat may be more accurately quantified with fat-saturated fast spin-echo MR imaging than with out-of-phase gradient-echo MR imaging, especially in patients with cirrhosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2372040539

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 185

Metadata

Authors
Qayyum, A., Goh, J. S., Kakar, S., Yeh, B. M., Merriman, R. B., & Coakley, F. V.
Venue
Radiology
Published
2005-11
Volume
237
Issue
2
Pages
507-511
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1983376473
Cited by
185
References
1
FWCI
5.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Liver Fat Quantification at MR Imaging: Comparison of Out-of-Phase Gradient-Echo and Fat-saturated Fast Spin-Echo Techniques—Initial Experience. https://app.cochat.ai/papers/10.1148/radiol.2372040539
The paper
Qayyum, A., Goh, J. S., Kakar, S., Yeh, B. M., Merriman, R. B., & Coakley, F. V. (2005). Accuracy of Liver Fat Quantification at MR Imaging: Comparison of Out-of-Phase Gradient-Echo and Fat-saturated Fast Spin-Echo Techniques—Initial Experience. Radiology. https://doi.org/10.1148/radiol.2372040539

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.