The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diffusion-weighted MR Imaging Sequence in the Detection of Postoperative Recurrent Cholesteatoma
Abstract
PURPOSE: To prospectively evaluate a fast spin-echo (SE) diffusion-weighted sequence for magnetic resonance (MR) imaging of recurrent cholesteatoma in patients who have undergone middle ear surgery. MATERIALS AND METHODS: The study was approved by the institutional review board, and informed consent was obtained from all patients. Twenty-four patients (10 female and 14 male patients; mean age, 44 years) who had undergone resection of cholesteatoma were referred for MR imaging. MR imaging was performed with a 1.5-T unit by using unenhanced diffusion-weighted fast SE imaging at b factors of 0 and 800 sec/mm(2), unenhanced T2-weighted fast SE imaging, unenhanced T1-weighted SE imaging, and delayed contrast material-enhanced T1-weighted imaging. Two radiologists evaluated the diffusion-weighted fast SE images for the presence of a high-signal-intensity cholesteatoma. Results from MR imaging were compared with reports from second- or third-look surgery. Interobserver agreement was assessed with the kappa statistic. RESULTS: A recurrent cholesteatoma was correctly identified in 13 of 14 patients with diffusion-weighted fast SE images obtained with a b factor of 800 sec/mm(2), for a positive predictive value of 93%. In patients without recurrent cholesteatoma, all diffusion-weighted fast SE MR images obtained with a b factor of 800 sec/mm(2) were correctly interpreted as showing no high signal intensity. Thus, the negative predictive value was 100%. Sensitivity and specificity were 100% (13 of 13 patients) and 91% (10 of 11 patients), respectively. Interobserver agreement was excellent (kappa = 0.92). The smallest recurrent cholesteatoma was 5 mm in diameter, and this was correctly detected with the diffusion-weighted fast SE sequence. CONCLUSION: Diffusion-weighted fast SE imaging enables the depiction of recurrent cholesteatoma in patients who have undergone middle ear surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Cited by
Diffusion-weighted MR Imaging in the Head and Neck
Thoeny, H. C., De Keyzer, F., & King, A. D. (2012) · Radiology · doi:10.1148/radiol.11101821 · Cited by 297
Extracranial applications of diffusion-weighted magnetic resonance imaging
Thoeny, H. C., & De Keyzer, F. (2007) · European Radiology · doi:10.1007/s00330-006-0547-0 · Cited by 269
Metadata
- Authors
- Dubrulle, F., Souillard, R., Chechin, D., Vaneecloo, F. M., Desaulty, A., & Vincent, C.
- Venue
- Radiology
- Published
- 2006-02
- Volume
- 238
- Issue
- 2
- Pages
- 604-610
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2124383192
- Cited by
- 195
- References
- 1
- FWCI
- 11.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.