CoChat

Asymptomatic Central Venous Stenosis in Hemodialysis Patients

Levit, Rebecca D., Cohen, Raphael M., Kwak, Andrew, Shlansky-Goldberg, Richard D., Clark, Timothy W. I., Patel, Aalpen A., Stavropoulos, S. William, Mondschein, Jeffrey I., Solomon, Jeffrey A., Tuite, Catherine M., Trerotola, Scott O. · 2006 · Radiology
Cited by 135

The DOI matches its Crossref record.

Abstract

PURPOSE: To retrospectively evaluate the natural history of high-grade (>50%) asymptomatic central venous stenosis (CVS) in hemodialysis patients and the outcome of serial treatment of CVS with percutaneous transluminal angioplasty (PTA). MATERIALS AND METHODS: The institutional review board granted exemption for this retrospective study, the need for informed consent was waived, and all data collection was in compliance with HIPAA. Patients with hemodialysis access requiring maintenance procedures between 1998 and 2004 and incidentally found to have ipsilateral (> or =50%) CVS were identified from a departmental database. Thirty-five patients (19 men, 16 women; mean age, 58.7 years) with 38 grafts met inclusion criteria, and 86 venograms were reviewed. CVS was measured by using venograms obtained before and after PTA, if performed. Patients with arm swelling, multiple CVS, indwelling catheters, and stents at the first encounter were excluded. CVS progression was calculated by dividing the change in the degree of stenosis by the time between venographic examinations. Wilcoxon rank sum test was used to evaluate differences in rate of CVS progression between treated and nontreated patients. RESULTS: Mean degree of CVS before intervention was 71% (range, 50%-100%). Sixty-two percent (53 of 86) of lesions had associated collateral vessels; 28% (24 of 86) of CVSs were not treated. Mean degree of stenosis in this group was 72% (range, 30%-100%); mean progression was -0.08 percentage point per day. No untreated CVS progressed to symptoms, stent placement, or additional CVS. Seventy-two percent (62 of 86) of CVSs were treated with PTA. Mean degree of stenosis in this group was 74% (range, 50%-100%) before and 40% (range, 0%-75%) after treatment; mean progression was 0.21 percentage point per day after treatment (P = .03). Six (8%) of 62 treatments were followed by CVS escalation; one patient developed arm swelling, four required stents, and four developed additional CVS. CONCLUSION: PTA of asymptomatic CVS greater than 50% in the setting of hemodialysis access maintenance procedures was associated with more rapid stenosis progression and escalation of lesions, compared with a nontreatment approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2383050119

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 135

Metadata

Authors
Levit, R. D., Cohen, R. M., Kwak, A., Shlansky-Goldberg, R. D., Clark, T. W. I., Patel, A. A., Stavropoulos, S. W., Mondschein, J. I., Solomon, J. A., Tuite, C. M., & Trerotola, S. O.
Venue
Radiology
Published
2006-03
Volume
238
Issue
3
Pages
1051-1056
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1991887960
Cited by
135
References
0
FWCI
12.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Asymptomatic Central Venous Stenosis in Hemodialysis Patients. https://app.cochat.ai/papers/10.1148/radiol.2383050119
The paper
Levit, R. D., Cohen, R. M., Kwak, A., Shlansky-Goldberg, R. D., Clark, T. W. I., Patel, A. A., Stavropoulos, S. W., Mondschein, J. I., Solomon, J. A., Tuite, C. M., & Trerotola, S. O. (2006). Asymptomatic Central Venous Stenosis in Hemodialysis Patients. Radiology. https://doi.org/10.1148/radiol.2383050119

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.