Pulmonary Nodules: Estimation of Malignancy at Thin-Section Helical CT—Effect of Computer-aided Diagnosis on Performance of Radiologists
The DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate the effect of a computer-aided diagnosis (CAD) system on the diagnostic performance of radiologists for the estimation of the malignancy of pulmonary nodules on thin-section helical computed tomographic (CT) scans. MATERIALS AND METHODS: The institutional review board approved use of the CT database; informed specific study-related consent was waived. The institutional review board approved participation of radiologists; informed consent was obtained from all observers. Thirty-three (18 malignant, 15 benign) pulmonary nodules of less than 3.0 cm in maximal diameter were evaluated. Receiver operating characteristic (ROC) analysis with a continuous rating scale was used to compare observer performance for the estimation of the likelihood of malignancy first without and then with the CAD system. The participants were 10 board-certified radiologists and nine radiology residents. RESULTS: For all 19 participants, the mean area under the best-fit ROC curve (A(z)) values achieved without and with the CAD system were 0.843 +/- 0.097 (standard deviation) and 0.924 +/- 0.043, respectively. The difference was significant (P = .021). The mean A(z) values achieved without and with the CAD system were 0.910 +/- 0.052 and 0.944 +/- 0.040, respectively, for the 10 board-certified radiologists (P = .190) and 0.768 +/- 0.078 and 0.901 +/- 0.036, respectively, for the nine radiology residents (P = .009). CONCLUSION: Use of the CAD system significantly (P = .009) improved the diagnostic performance of radiology residents for assessment of the malignancy of pulmonary nodules; however, it did not improve that of board-certified radiologists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cheng, J.-Z., Ni, D., Chou, Y.-H., Qin, J., Tiu, C.-M., Chang, Y.-C., Huang, C.-S., Shen, D., & Chen, C.-M. (2016) · Scientific Reports · doi:10.1038/srep24454 · Cited by 755
A deep learning framework for supporting the classification of breast lesions in ultrasound images
Han, S., Kang, H.-K., Jeong, J.-Y., Park, M.-H., Kim, W., Bang, W.-C., & Seong, Y.-K. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa82ec · Cited by 358
Park, C. M., Goo, J. M., Lee, H. J., Lee, C. H., Chun, E. J., & Im, J.-G. (2007) · RadioGraphics · doi:10.1148/rg.272065061 · Cited by 294
Improving the radiologist-CAD interaction: designing for appropriate trust
Jorritsma, W., Cnossen, F., & van Ooijen, P. M. A. (2015) · Clinical Radiology · doi:10.1016/j.crad.2014.09.017 · Cited by 61
Li, D., Pehrson, L. M., Lauridsen, C. A., Tøttrup, L., Fraccaro, M., Elliott, D., Zając, H. D., Darkner, S., Carlsen, J. F., & Nielsen, M. B. (2021) · Diagnostics · doi:10.3390/diagnostics11122206 · Cited by 35
Metadata
- Authors
- Awai, K., Murao, K., Ozawa, A., Nakayama, Y., Nakaura, T., Liu, D., Kawanaka, K., Funama, Y., Morishita, S., & Yamashita, Y.
- Venue
- Radiology
- Published
- 2006-04
- Volume
- 239
- Issue
- 1
- Pages
- 276-284
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2159068781
- Cited by
- 85
- References
- 0
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulmonary Nodules: Estimation of Malignancy at Thin-Section Helical CT—Effect of Computer-aided Diagnosis on Performance of Radiologists. https://app.cochat.ai/papers/10.1148/radiol.2383050167
- The paper
- Awai, K., Murao, K., Ozawa, A., Nakayama, Y., Nakaura, T., Liu, D., Kawanaka, K., Funama, Y., Morishita, S., & Yamashita, Y. (2006). Pulmonary Nodules: Estimation of Malignancy at Thin-Section Helical CT—Effect of Computer-aided Diagnosis on Performance of Radiologists. Radiology. https://doi.org/10.1148/radiol.2383050167
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.