Screening Mammograms: Interpretation with Computer-aided Detection—Prospective Evaluation
The DOI matches its Crossref record.
Abstract
PURPOSE: To prospectively determine the effect of a commercially available computer-aided detection (CAD) system on interpretations of screening mammograms. MATERIALS AND METHODS: Institutional review board approval was granted; informed consent and HIPAA compliance were waived. A total of 21 349 screening mammograms obtained in 18 096 women were interpreted first without and then with review of CAD images to determine the effect of CAD analysis on the screening breast cancer detection rate, recall rate, and positive predictive value (PPV) for biopsy. The percentage of total cancers detected by the radiologists independent of CAD and the percentage correctly marked by the CAD system were determined. RESULTS: On the basis of pre-CAD interpretations, 2101 patients were recalled for diagnostic evaluation, 256 biopsies were performed, and 105 breast cancers were diagnosed. The breast cancer detection rate per 1000 screening mammograms was 4.92 (105 of 21 349 mammograms), the recall rate was 9.84% (2101 of 21 349 mammograms), and the PPV for biopsy was 41.0% (105 of 256 biopsies). After CAD image review, 199 additional patients were recalled, 21 additional biopsies were performed, and eight additional cancers were detected. The effect was a 7.62% (eight of 105) increase in the number of breast cancers detected, an increase in the recall rate to 10.77% (2300 of 21 349 mammograms), and a slight decrease in the PPV to 40.8% (113 of 277 biopsies). Radiologists detected 92.9% (105 of 113 cancers) of the total cancers, and CAD correctly marked 76.1% (86 of 113 cancers). CONCLUSION: The use of CAD improved the detection of breast cancer, with an acceptable increase in the recall rate and a minimal increase in the number of biopsies with benign results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
“[5] Morton MJ, Whaley DH, Brandt KR, Amrami KK.”
BackgroundDetecting and classifying lesions in mammograms with Deep Learning
Ribli, D., Horváth, A., Unger, Z., Pollner, P., & Csabai, I. (2018) · Scientific Reports · doi:10.1038/s41598-018-22437-z · Cited by 696
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
The Potential of Radiomic-Based Phenotyping in Precision Medicine: A Review
Aerts, H. J. W. L. (2016) · JAMA Oncology · doi:10.1001/jamaoncol.2016.2631 · Cited by 669
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
Nothacker, M., Duda, V., Hahn, M., Warm, M., Degenhardt, F., Madjar, H., Weinbrenner, S., & Albert, U.-S. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-335 · Cited by 314
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Single Reading with Computer-Aided Detection for Screening Mammography
Gilbert, F. J., Astley, S. M., Gillan, M. G. C., Agbaje, O. F., Wallis, M. G., James, J., Boggis, C. R. M., & Duffy, S. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0803545 · Cited by 296
Geras, K. J., Mann, R. M., & Moy, L. (2019) · Radiology · doi:10.1148/radiol.2019182627 · Cited by 295
Effectiveness of Computer-Aided Detection in Community Mammography Practice
Fenton, J. J., Abraham, L., Taplin, S. H., Geller, B. M., Carney, P. A., D'Orsi, C., Elmore, J. G., Barlow, W. E., & for the Breast Cancer Surveillance Consortium (2011) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djr206 · Cited by 168
“However, matched studies typically impose the restriction that radiologists can only upgrade final BI-RADS assessments after viewing CAD output, resulting in the recall of women who would not have been recalled in the absence of CAD (11,13,36,37).”
Background
Metadata
- Authors
- Morton, M. J., Whaley, D. H., Brandt, K. R., & Amrami, K. K.
- Venue
- Radiology
- Published
- 2006-05
- Volume
- 239
- Issue
- 2
- Pages
- 375-383
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2152034657
- Cited by
- 218
- References
- 0
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.