Classification of Breast Lesions with Multimodality Computer-aided Diagnosis: Observer Study Results on an Independent Clinical Data Set
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate a computer-aided diagnosis multimodality intelligent workstation as an aid to radiologists in the interpretation of mammograms and breast sonograms. MATERIALS AND METHODS: An institutional review board approved the protocol for an observer study with signed consent, as well as the retrospective use of the mammograms, sonograms, and clinical data with waiver of consent. The HIPAA-compliant observer study was conducted with five breast radiologists and five breast imaging fellows, all of whom gave confidence ratings and patient management decisions, both without and with the computer aid, for 97 lesions that were unknown to both the observers and the computer. The performance of each observer without and with the computer aid was quantified by using four performance measures: area under the receiver operating characteristic curve (A(z)) value, partial A(z) value, sensitivity, and specificity. The statistical significance of the differences in the performance measures without and with the computer aid was determined by using a two-tailed t test for paired data. RESULTS: Use of the computer aid resulted in an improvement of the average performance of the 10 observers, as measured by means of a statistically significant increase in A(z) value (0.87-0.92; P < .001), partial A(z) value (0.47-0.68; P < .001), and sensitivity (0.88-0.93; P = .005). A statistically significant difference was not found in the specificity without and with the computer aid (0.66-0.69; P = .20). CONCLUSION: Use of multimodality intelligent workstations can improve the performance of radiologists in the task of differentiating malignant and benign lesions at mammography and sonography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Tiwari, R. C., Murray, T., Ghafoor, A., Samuels, A., Ward, E., Feuer, E. J., & Thun, M. J. (2004) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.54.1.8 · Cited by 3,984
Cited by
Breast cancer detection using deep learning: Datasets, methods, and challenges ahead
din, N. M. U., Dar, R. A., Rasool, M., & Assad, A. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106073 · Cited by 363
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Self-citationComputer-aided Diagnosis: How to Move from the Laboratory to the Clinic
van Ginneken, B., Schaefer-Prokop, C. M., & Prokop, M. (2011) · Radiology · doi:10.1148/radiol.11091710 · Cited by 306
Unregistered Multiview Mammogram Analysis with Pre-trained Deep Learning Models
Carneiro, G., Nascimento, J., & Bradley, A. P. (2015) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-24574-4_78 · Cited by 235
“, mammograms and sonograms) have been shown to improve the average performance of radiologists [17].”
BackgroundBreast Image Analysis for Risk Assessment, Detection, Diagnosis, and Treatment of Cancer
Giger, M. L., Karssemeijer, N., & Schnabel, J. A. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152416 · Cited by 206
“Output from a CADx system, an example of which is shown in Figure 6, could consist of individual feature values, merged features in terms of a lesion signature (potentially related to the likelihood of malignancy), histograms or clusters demonstrating relationship to known cases, and/or similar cases drawn from a data…”
MethodSelf-citationCADx of mammographic masses and clustered microcalcifications: A review
Elter, M., & Horsch, A. (2009) · Medical Physics · doi:10.1118/1.3121511 · Cited by 204
“Drukker et al. 111,112 proposed a multimodal CADx approach that incorporates information from mammograms and breast sonography.”
BackgroundAutomated Analysis of Unregistered Multi-View Mammograms With Deep Learning
Carneiro, G., Nascimento, J., & Bradley, A. P. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2751523 · Cited by 196
“The use of multiple views of the same lesion has also been explored [38], [43], and current evidence suggests that such approaches can potentially improve the performance of the system.”
BackgroundBhooshan, N., Giger, M. L., Jansen, S. A., Li, H., Lan, L., & Newstead, G. M. (2010) · Radiology · doi:10.1148/radiol.09090838 · Cited by 193
Self-citationCurrent status and future directions of computer-aided diagnosis in mammography
Nishikawa, R. M. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.009 · Cited by 175
Image based computer aided diagnosis system for cancer detection
Lee, H., & Chen, Y.-P. P. (2015) · Expert Systems with Applications · doi:10.1016/j.eswa.2015.02.005 · Cited by 158
Evaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA
Gallas, B. D., Chan, H.-P., D’Orsi, C. J., Dodd, L. E., Giger, M. L., Gur, D., Krupinski, E. A., Metz, C. E., Myers, K. J., Obuchowski, N. A., et al. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.12.016 · Cited by 81
“However, unless the two scales are explicitly linked, inconsistencies cannot be fully eliminated (104,105).”
BackgroundSelf-citationImproving the radiologist-CAD interaction: designing for appropriate trust
Jorritsma, W., Cnossen, F., & van Ooijen, P. M. A. (2015) · Clinical Radiology · doi:10.1016/j.crad.2014.09.017 · Cited by 61
Metadata
- Authors
- Horsch, K., Giger, M. L., Vyborny, C. J., Lan, L., Mendelson, E. B., & Hendrick, R. E.
- Venue
- Radiology
- Published
- 2006-08
- Volume
- 240
- Issue
- 2
- Pages
- 357-368
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2171751663
- Cited by
- 101
- References
- 1
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.