Single Reading with Computer-aided Detection and Double Reading of Screening Mammograms in the United Kingdom National Breast Screening Program
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To retrospectively determine if the use of a computer-aided detection (CAD) system can improve the performance of single reading of screening mammograms to match that of double reading in the United Kingdom. MATERIALS AND METHODS: Local research ethics committee approval was obtained; informed consent was not required. This study included a sample of 10 267 mammograms obtained in women aged 50 years or older who underwent routine screening at one of two breast screening centers in 1996. Mammograms that were double read in 1996 were randomly allocated to be re-read by eight different radiologists using CAD. The cancer detection and recall rates from double reading and single reading with CAD were compared. Statistical significance and confidence intervals were calculated with the McNemar test to account for the matched nature of the data. RESULTS: Single reading with CAD led to a cancer detection rate that was significantly (P = .02) higher than that achieved with double reading: 6.5% more cancers were detected by means of single reading with CAD than by means of double reading. However, the recall rate was higher for single reading with CAD than for double reading (8.6% vs 6.5%, respectively; P < .001). This was equivalent to relative increases of 15% and 32% in the cancer detection and recall rates, respectively. CONCLUSION: Single reading with CAD leads to an improved cancer detection rate and an increased recall rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Note on the Sampling Error of the Difference Between Correlated Proportions or Percentages
McNemar, Q. (1947) · Psychometrika · doi:10.1007/bf02295996 · Cited by 4,754
Trials to assess equivalence: the importance of rigorous methods: Fig 1
Jones, B., Jarvis, P., Lewis, J. A., & Ebbutt, A. F. (1996) · BMJ · doi:10.1136/bmj.313.7048.36 · Cited by 1,032
Cited by
Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
“Data were pooled from 5 mammography registries that participate in the Breast Cancer Surveillance Consortium (BCSC)20 funded by the National Cancer Institute: (1) the San Francisco Mammography Registry, (2) the New Mexico Mammography Advocacy Project, (3) the Vermont Breast Cancer Surveillance System, (4) the New Hamp…”
MethodGiger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Single Reading with Computer-Aided Detection for Screening Mammography
Gilbert, F. J., Astley, S. M., Gillan, M. G. C., Agbaje, O. F., Wallis, M. G., James, J., Boggis, C. R. M., & Duffy, S. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0803545 · Cited by 296
Self-citationBrentnall, A. R., Harkness, E. F., Astley, S. M., Donnelly, L. S., Stavrinos, P., Sampson, S., Fox, L., Sergeant, J. C., Harvie, M. N., Wilson, M., et al. (2015) · Breast Cancer Research · doi:10.1186/s13058-015-0653-5 · Cited by 252
“In total, 18 professionals assessed density; this group consisted of 10 radiologists, 2 breast physicians and 6 advanced practitioner radiographers, many of whom had participated in an earlier study of density [24].”
BackgroundSelf-citationImproving the radiologist-CAD interaction: designing for appropriate trust
Jorritsma, W., Cnossen, F., & van Ooijen, P. M. A. (2015) · Clinical Radiology · doi:10.1016/j.crad.2014.09.017 · Cited by 61
Metadata
- Authors
- Gilbert, F. J., Astley, S. M., McGee, M. A., Gillan, M. G. C., Boggis, C. R. M., Griffiths, P. M., & Duffy, S. W.
- Venue
- Radiology
- Published
- 2006-10
- Volume
- 241
- Issue
- 1
- Pages
- 47-53
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1967499133
- Cited by
- 96
- References
- 2
- FWCI
- 8.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single Reading with Computer-aided Detection and Double Reading of Screening Mammograms in the United Kingdom National Breast Screening Program. https://app.cochat.ai/papers/10.1148/radiol.2411051092
- The paper
- Gilbert, F. J., Astley, S. M., McGee, M. A., Gillan, M. G. C., Boggis, C. R. M., Griffiths, P. M., & Duffy, S. W. (2006). Single Reading with Computer-aided Detection and Double Reading of Screening Mammograms in the United Kingdom National Breast Screening Program. Radiology. https://doi.org/10.1148/radiol.2411051092
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.