Prevalence and Clinical Importance of Aortic Valve Calcification Detected Incidentally on CT Scans: Comparison with Echocardiography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate retrospectively the prevalence and grade of aortic valve calcification incidentally detected on chest multi-detector row computed tomographic (CT) scans and to compare the grade of calcification with the severity of aortic valve disease as assessed with echocardiography. MATERIALS AND METHODS: Patient informed consent was waived by the institutional board on medical ethics that approved this study. The authors identified 402 patients (231 men and 171 women; mean age, 62.5 years +/- 12.1) of 1820 patients who underwent chest multi-detector row CT between July 2001 and August 2004 and also underwent echocardiography. Aortic valve calcification at multi-detector row CT was visually graded on a scale ranging from 0 to 4 (0 = no calcification, 4 = severe calcification). CT findings were correlated with hemodynamic data obtained at echocardiography. Patients without aortic stenosis were compared with patients with aortic stenosis. The Student t test, Spearman correlation coefficient, chi(2) analysis, and an unweighted kappa test were used to compare results. RESULTS: Aortic valve calcification was noted on multi-detector row CT scans in 72 of the 402 patients (18%). Twelve of 20 patients (60%) with grade 3 or grade 4 calcification on CT scans had aortic stenosis at echocardiography, compared with only nine of 382 patients (2.4%) with grade 0-2 calcification (P < .001). Significant correlations were observed between the grade of aortic valve calcification and the echocardiographically determined mean (r = 0.45, P = .03) and peak transvalvular gradient (r = 0.47, P = .03). There was substantial agreement between the grade of valve calcification at multi-detector row CT and the severity of aortic valve disease at echocardiography (kappa = 0.67). CONCLUSION: Aortic valve calcification was an incidental finding on 18% of multi-detector row CT scans. The grade of aortic valve calcification is correlated with the hemodynamic severity of aortic valve disease as determined with echocardiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Factors Associated With Calcific Aortic Valve Disease
Stewart, B. F., Siscovick, D., Lind, B. K., Gardin, J. M., Gottdiener, J. S., Smith, V. E., Kitzman, D. W., & Otto, C. M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00563-3 · Cited by 2,029
Cited by
Calcification in Aortic Stenosis
Pawade, T. A., Newby, D. E., & Dweck, M. R. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.05.066 · Cited by 397
Cueff, C., Serfaty, J.-M., Cimadevilla, C., Laissy, J.-P., Himbert, D., Tubach, F., Duval, X., Iung, B., Enriquez-Sarano, M., Vahanian, A., et al. (2011) · Heart · doi:10.1136/hrt.2010.198853 · Cited by 385
Incidental findings in imaging diagnostic tests: a systematic review
Lumbreras, B., Donat, L., & Hernández-Aguado, I. (2010) · The British Journal of Radiology · doi:10.1259/bjr/98067945 · Cited by 370
Soni, A. V., & Miller, S. W. (2009) · Cardiac Imaging · doi:10.1016/b978-0-323-05527-7.50013-5 · Cited by 311
Why and How to Measure Aortic Valve Calcification in Patients With Aortic Stenosis
Pawade, T., Sheth, T., Guzzetti, E., Dweck, M. R., & Clavel, M.-A. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.01.045 · Cited by 274
Metadata
- Authors
- Koos, R., Kühl, H. P., Mühlenbruch, G., Wildberger, J. E., Günther, R. W., & Mahnken, A. H.
- Venue
- Radiology
- Published
- 2006-10
- Volume
- 241
- Issue
- 1
- Pages
- 76-82
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2143399483
- Cited by
- 90
- References
- 1
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.