CoChat

Pancreatic Adenocarcinoma: Value of Multidetector CT Angiography in Preoperative Evaluation

Zamboni, Giulia A., Kruskal, Jonathan B., Vollmer, Charles M., Baptista, Jovanna, Callery, Mark P., Raptopoulos, Vassilios D. · 2007 · Radiology
Cited by 139

The DOI matches its Crossref record.

Abstract

PURPOSE: To retrospectively assess the sensitivity and specificity of multidetector computed tomographic (CT) angiography in the preoperative evaluation of pancreatic adenocarcinoma by using surgical findings as the reference standard. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant study; informed consent was waived. We reviewed CT reports, surgical notes, and pathology reports from 114 patients with pancreatic or distal cholangiocarcinoma who underwent multidetector CT angiography and surgery at our institution between March 2003 and March 2006. When CT findings and surgical reports were discordant, radiologists experienced in pancreatic imaging retrospectively reviewed images for lesion resectability; four-, eight-, 16-, and 64-row CT scanners were used in 54, 19, 25, and 16 patients, respectively. Collimation of 1.25 mm was used for four- and eight-row CT and 0.5 or 0.625 mm for 16- and 64-row CT. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for resectability were calculated for initial clinical interpretation and blinded retrospective review. RESULTS: Eighty-eight patients had resectable lesions according to CT angiographic criteria (group A: 46 women, 42 men; mean age, 67 years; age range, 39-85 years): resection was aborted in 10 patients (11%). Twenty-six patients underwent surgery despite lesion unresectability assessed according to CT angiographic criteria (group B: 16 women, 10 men; mean age, 62 years; age range, 33-83 years); all lesions were confirmed as unresectable. The initial clinical interpretation of CT angiographic scans in all 114 patients had 100% sensitivity in the detection of resectability, 72% specificity, 89% PPV, and 100% NPV. These parameters did not appear to vary among different types of scanner. With the blinded retrospective evaluation by experienced readers, specificity increased to 94% and PPV to 98%, with no difference in sensitivity and NPV. CONCLUSION: Multidetector CT angiography is an effective preoperative tool that reduces the number of aborted pancreatic resections; there is no evidence from this retrospective study suggesting varying results from the various generations of multidetector CT scanners used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2453061795

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 139

Metadata

Authors
Zamboni, G. A., Kruskal, J. B., Vollmer, C. M., Baptista, J., Callery, M. P., & Raptopoulos, V. D.
Venue
Radiology
Published
2007-12
Volume
245
Issue
3
Pages
770-778
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2151560242
Cited by
139
References
0
FWCI
3.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pancreatic Adenocarcinoma: Value of Multidetector CT Angiography in Preoperative Evaluation. https://app.cochat.ai/papers/10.1148/radiol.2453061795
The paper
Zamboni, G. A., Kruskal, J. B., Vollmer, C. M., Baptista, J., Callery, M. P., & Raptopoulos, V. D. (2007). Pancreatic Adenocarcinoma: Value of Multidetector CT Angiography in Preoperative Evaluation. Radiology. https://doi.org/10.1148/radiol.2453061795

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.