CoChat

Pure Ductal Carcinoma in Situ: Kinetic and Morphologic MR Characteristics Compared with Mammographic Appearance and Nuclear Grade

Jansen, Sanaz A., Newstead, Gillian M., Abe, Hiroyuki, Shimauchi, Akiko, Schmidt, Robert A., Karczmar, Gregory S. · 2007 · Radiology
Cited by 168

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

PURPOSE: To retrospectively compare the kinetic and morphologic characteristics of pure ductal carcinoma in situ (DCIS) lesions depicted on dynamic contrast material-enhanced magnetic resonance (MR) images with the nuclear grade and conventional mammographic appearance of these lesions. MATERIALS AND METHODS: This HIPAA-compliant retrospective study was institutional review board approved, and informed patient consent was waived. Seventy-eight patients with 79 histologically proved pure DCIS lesions were selected. There were 17 low-nuclear-grade, 26 intermediate-nuclear-grade, 30 high-nuclear-grade, and six unclassified lesions. Sixty-five lesions were classified as fine pleomorphic, fine linear, or fine linear-branching calcifications (n = 31); amorphous or indistinct calcifications (n = 18); noncalcified mass (n = 10); or occult (n = 6) at conventional (x-ray) mammography. One experienced radiologist analyzed lesion morphology and kinetic curve shape according to the Breast Imaging Reporting and Data System lexicon. Initial enhancement percentage, time to peak enhancement (T(peak)), and signal enhancement ratio (a measure of washout) were calculated for each lesion. RESULTS: Of the 79 pure DCIS lesions, 20 (25%) exhibited enhancement plateau curves and 35 (44%) exhibited washout curves. The lesions with a masslike appearance on mammograms exhibited more suspicious kinetic characteristics (mean T(peak) approximately 2 minutes) than did the lesions with amorphous or indistinct calcifications (mean T(peak) = 4.4 minutes). There was no significant difference in enhancement kinetic properties across the nuclear grades. Lesion morphology was predominantly nonmass, with clumped or heterogeneous enhancement in a segmental or linear distribution. CONCLUSION: The pure DCIS lesions exhibited washout, plateau, and persistent enhancement curves. Enhancement kinetic characteristics varied with mammographic appearance but not with nuclear grade. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/245/3/684/DC1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2453062061

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 168

Metadata

Authors
Jansen, S. A., Newstead, G. M., Abe, H., Shimauchi, A., Schmidt, R. A., & Karczmar, G. S.
Venue
Radiology
Published
2007-12
Volume
245
Issue
3
Pages
684-691
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2128620974
Cited by
168
References
20
FWCI
8.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.