Breast-specific Gamma Imaging as an Adjunct Imaging Modality for the Diagnosis of Breast Cancer
Abstract
PURPOSE: To retrospectively determine the sensitivity and specificity of breast-specific gamma imaging (BSGI) for the detection of breast cancer by using pathologic results as the reference standard. MATERIALS AND METHODS: This study was Institutional Review Board approved and Health Insurance Portability and Accountability Act compliant. Informed consent was obtained for participants who were not imaged as part of their clinical protocol but were participating in other Institutional Review Board-approved studies that used BSGI. A retrospective review of 146 women (aged 32-98 years) undergoing BSGI and breast biopsy was performed. Patients underwent BSGI with intravenous injection of 30 mCi (1110 MBq) of technetium 99 ((99m)Tc)-sestamibi and were imaged in craniocaudal and mediolateral oblique projections. Study images were assigned scores, and scores were classified as positive (focal increased radiotracer uptake) or negative (no uptake or scattered heterogeneous physiologic uptake) and compared with biopsy results. The sensitivity, specificity, and positive and negative predictive values were determined. RESULTS: In 146 patients, 167 lesions underwent biopsy, of which 83 (16 ductal carcinoma in situ [DCIS] and 67 invasive cancers) were malignant. Of 84 nonmalignant lesions, 82 were benign and two showed atypical histologic results (one atypical lobular hyperplasia and one lobular carcinoma in situ). BSGI helped detect cancer in 80 of 83 malignant lesions with a sensitivity of 96.4% (95% confidence interval [CI]: 92%, 99%) and correctly identified 50 of 84 nonmalignant lesions as negative for cancer with a specificity of 59.5% (95% CI: 49%, 70%). The positive predictive value for 80 of 114 malignant lesions with a BSGI examination with findings positive for cancer was 68.8% (95% CI: 60%, 78%) and the negative predictive value for 50 of 53 nonmalignant lesions was 94.3% (95% CI: 88%, 99%). The smallest invasive cancer and DCIS detected were both 1 mm. BSGI helped detect occult cancer not visualized at mammography or ultrasonography in six patients. CONCLUSION: BSIG has high sensitivity (96.4%) and moderate specificity (59.5%) helping detect breast cancers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gail, M. H., Brinton, L. A., Byar, D. P., Corle, D. K., Green, S. B., Schairer, C., & Mulvihill, J. J. (1989) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/81.24.1879 · Cited by 3,334
Statistical Analysis of Correlated Data Using Generalized Estimating Equations: An Orientation
Hanley, J. A. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwf215 · Cited by 2,185
Cited by
Breast cancer diagnosis: Imaging techniques and biochemical markers
Jafari, S. H., Saadatpour, Z., Salmaninejad, A., Momeni, F., Mokhtari, M., Nahand, J. S., Rahmati, M., Mirzaei, H., & Kianmehr, M. (2018) · Journal of Cellular Physiology · doi:10.1002/jcp.26379 · Cited by 410
Radiation Doses and Cancer Risks from Breast Imaging Studies
Hendrick, R. E. (2010) · Radiology · doi:10.1148/radiol.10100570 · Cited by 360
Metadata
- Authors
- Brem, R. F., Floerke, A. C., Rapelyea, J. A., Teal, C., Kelly, T., & Mathur, V.
- Venue
- Radiology
- Published
- 2008-06
- Volume
- 247
- Issue
- 3
- Pages
- 651-657
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2134960600
- Cited by
- 177
- References
- 2
- FWCI
- 11.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breast-specific Gamma Imaging as an Adjunct Imaging Modality for the Diagnosis of Breast Cancer. https://app.cochat.ai/papers/10.1148/radiol.2473061678
- The paper
- Brem, R. F., Floerke, A. C., Rapelyea, J. A., Teal, C., Kelly, T., & Mathur, V. (2008). Breast-specific Gamma Imaging as an Adjunct Imaging Modality for the Diagnosis of Breast Cancer. Radiology. https://doi.org/10.1148/radiol.2473061678
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.