Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record.

Glioma Grading by Using Histogram Analysis of Blood Volume Heterogeneity from MR-derived Cerebral Blood Volume Maps

Emblem, Kyrre E., Nedregaard, Baard, Nome, Terje, Due-Tonnessen, Paulina, Hald, John K., Scheie, David, Borota, Olivera Casar, Cvancarova, Milada, Bjornerud, Atle · 2008 · Radiology

Abstract

PURPOSE: To retrospectively compare the diagnostic accuracy of an alternative method used to grade gliomas that is based on histogram analysis of normalized cerebral blood volume (CBV) values from the entire tumor volume (obtained with the histogram method) with that of the hot-spot method, with histologic analysis as the reference standard. MATERIALS AND METHODS: The medical ethics committee approved this study, and all patients provided informed consent. Fifty-three patients (24 female, 29 male; mean age, 48 years; age range, 14-76 years) with histologically confirmed gliomas were examined with dynamic contrast material-enhanced 1.5-T magnetic resonance (MR) imaging. CBV maps were created and normalized to unaffected white matter (normalized CBV maps). Four neuroradiologists independently measured the distribution of whole-tumor normalized CBVs and analyzed this distribution by classifying the values into area-normalized bins. Glioma grading was performed by assessing the normalized peak height of the histogram distributions. Logistic regression analysis and interobserver agreement were used to compare the proposed method with a hot-spot method in which only the maximum normalized CBV was used. RESULTS: For the histogram method, diagnostic accuracy was independent of the observer. Interobserver agreement was almost perfect for the histogram method (kappa = 0.923) and moderate for the hot-spot method (kappa = 0.559). For all observers, sensitivity was higher with the histogram method (90%) than with the hot-spot method (55%-76%). CONCLUSION: Glioma grading based on histogram analysis of normalized CBV heterogeneity is an alternative to the established hot-spot method, as it offers increased diagnostic accuracy and interobserver agreement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2473070571

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Emblem, K. E., Nedregaard, B., Nome, T., Due-Tonnessen, P., Hald, J. K., Scheie, D., Borota, O. C., Cvancarova, M., & Bjornerud, A.
Venue
Radiology
Published
2008-06
Volume
247
Issue
3
Pages
808-817
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2150441550
Cited by
159
References
0
FWCI
4.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glioma Grading by Using Histogram Analysis of Blood Volume Heterogeneity from MR-derived Cerebral Blood Volume Maps. https://app.cochat.ai/papers/10.1148/radiol.2473070571
The paper
Emblem, K. E., Nedregaard, B., Nome, T., Due-Tonnessen, P., Hald, J. K., Scheie, D., Borota, O. C., Cvancarova, M., & Bjornerud, A. (2008). Glioma Grading by Using Histogram Analysis of Blood Volume Heterogeneity from MR-derived Cerebral Blood Volume Maps. Radiology. https://doi.org/10.1148/radiol.2473070571

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.