Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 366

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Prospective versus Retrospective ECG Gating for 64-Detector CT of the Coronary Arteries: Comparison of Image Quality and Patient Radiation Dose

Shuman, William P., Branch, Kelley R., May, Janet M., Mitsumori, Lee M., Lockhart, David W., Dubinsky, Theodore J., Warren, Bill H., Caldwell, James H. · 2008 · Radiology

Abstract

PURPOSE: To compare image quality and patient radiation dose in a group of patients who underwent 64-detector computed tomography (CT) coronary angiography performed with prospective electrocardiographic (ECG) gating with image quality and radiation dose in a group of patients matched for clinical features who underwent 64-detector CT coronary angiography performed with retrospective ECG gating. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant study, and the informed consent requirement was waived due to the retrospective study design. Two independent reviewers separately scored coronary artery segment image quality and overall image quality for 100 cardiac CT studies (50 in each group). Interobserver variability was calculated. Patient radiation dose for the actual examination z-axis length was recorded, and a normalized dose was calculated for a 12-cm z-axis length of a typical heart. RESULTS: The two groups matched well for clinical characteristics and CT parameters. There was good agreement for coronary artery segment image quality scores between the independent reviewers (kappa = 0.72). Of the 1253 coronary artery segments scored, the number of coronary artery segments that could not be evaluated in each group was similar (1.1% [seven of 614] in the prospective group vs 1.5% [10 of 647] in the retrospective group, P = .53). Image quality scores were not significantly different when matched for chest cross-sectional area (P > .05). Mean patient radiation dose was 77% lower for prospective gating (4.2 mSv) than for retrospective gating (18.1 mSv) (P < .01). CONCLUSION: Use of 64-detector CT coronary angiography performed with prospective ECG gating has similar subjective image quality scores but 77% lower patient radiation dose when compared with use of retrospective ECG gating.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2482072192

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 366

Metadata

Authors
Shuman, W. P., Branch, K. R., May, J. M., Mitsumori, L. M., Lockhart, D. W., Dubinsky, T. J., Warren, B. H., & Caldwell, J. H.
Venue
Radiology
Published
2008-08
Volume
248
Issue
2
Pages
431-437
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2164700212
Cited by
366
References
10
FWCI
50.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective versus Retrospective ECG Gating for 64-Detector CT of the Coronary Arteries: Comparison of Image Quality and Patient Radiation Dose. https://app.cochat.ai/papers/10.1148/radiol.2482072192
The paper
Shuman, W. P., Branch, K. R., May, J. M., Mitsumori, L. M., Lockhart, D. W., Dubinsky, T. J., Warren, B. H., & Caldwell, J. H. (2008). Prospective versus Retrospective ECG Gating for 64-Detector CT of the Coronary Arteries: Comparison of Image Quality and Patient Radiation Dose. Radiology. https://doi.org/10.1148/radiol.2482072192

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.