Prospective versus Retrospective ECG Gating for 64-Detector CT of the Coronary Arteries: Comparison of Image Quality and Patient Radiation Dose
Abstract
PURPOSE: To compare image quality and patient radiation dose in a group of patients who underwent 64-detector computed tomography (CT) coronary angiography performed with prospective electrocardiographic (ECG) gating with image quality and radiation dose in a group of patients matched for clinical features who underwent 64-detector CT coronary angiography performed with retrospective ECG gating. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant study, and the informed consent requirement was waived due to the retrospective study design. Two independent reviewers separately scored coronary artery segment image quality and overall image quality for 100 cardiac CT studies (50 in each group). Interobserver variability was calculated. Patient radiation dose for the actual examination z-axis length was recorded, and a normalized dose was calculated for a 12-cm z-axis length of a typical heart. RESULTS: The two groups matched well for clinical characteristics and CT parameters. There was good agreement for coronary artery segment image quality scores between the independent reviewers (kappa = 0.72). Of the 1253 coronary artery segments scored, the number of coronary artery segments that could not be evaluated in each group was similar (1.1% [seven of 614] in the prospective group vs 1.5% [10 of 647] in the retrospective group, P = .53). Image quality scores were not significantly different when matched for chest cross-sectional area (P > .05). Mean patient radiation dose was 77% lower for prospective gating (4.2 mSv) than for retrospective gating (18.1 mSv) (P < .01). CONCLUSION: Use of 64-detector CT coronary angiography performed with prospective ECG gating has similar subjective image quality scores but 77% lower patient radiation dose when compared with use of retrospective ECG gating.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new look at the statistical model identification
Akaike, H. (1974) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1974.1100705 · Cited by 51,879
Regression Models for Ordinal Data
McCullagh, P. (1980) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1980.tb01109.x · Cited by 4,453
Maximum Likelihood Estimation of Misspecified Models
White, H. (1982) · Econometrica · doi:10.2307/1912526 · Cited by 4,098
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Hausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Earls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Hamon, M., Biondi-Zoccai, G. G. L., Malagutti, P., Agostoni, P., Morello, R., Valgimigli, M., & Hamon, M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.028 · Cited by 460
Step‐and‐shoot data acquisition and reconstruction for cardiac x‐ray computed tomography
Hsieh, J., Londt, J., Vass, M., Li, J., Tang, X., & Okerlund, D. (2006) · Medical Physics · doi:10.1118/1.2361078 · Cited by 228
Multidetector Computed Tomography for the Diagnosis of Coronary Artery Disease: A Systematic Review
Stein, P. D., Beemath, A., Kayali, F., Skaf, E., Sánchez, J., & Olson, R. E. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.06.071 · Cited by 154
Cited by
Achenbach, S., Marwan, M., Ropers, D., Schepis, T., Pflederer, T., Anders, K., Kuettner, A., Daniel, W. G., Uder, M., & Lell, M. M. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp470 · Cited by 585
Abbara, S., Arbab-Zadeh, A., Callister, T. Q., Desai, M. Y., Mamuya, W., Thomson, L., & Weigold, W. G. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.03.004 · Cited by 580
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
High-pitch spiral acquisition: A new scan mode for coronary CT angiography
Achenbach, S., Marwan, M., Schepis, T., Pflederer, T., Bruder, H., Allmendinger, T., Petersilka, M., Anders, K., Lell, M., Kuettner, A., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.02.008 · Cited by 258
Metadata
- Authors
- Shuman, W. P., Branch, K. R., May, J. M., Mitsumori, L. M., Lockhart, D. W., Dubinsky, T. J., Warren, B. H., & Caldwell, J. H.
- Venue
- Radiology
- Published
- 2008-08
- Volume
- 248
- Issue
- 2
- Pages
- 431-437
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2164700212
- Cited by
- 366
- References
- 10
- FWCI
- 50.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prospective versus Retrospective ECG Gating for 64-Detector CT of the Coronary Arteries: Comparison of Image Quality and Patient Radiation Dose. https://app.cochat.ai/papers/10.1148/radiol.2482072192
- The paper
- Shuman, W. P., Branch, K. R., May, J. M., Mitsumori, L. M., Lockhart, D. W., Dubinsky, T. J., Warren, B. H., & Caldwell, J. H. (2008). Prospective versus Retrospective ECG Gating for 64-Detector CT of the Coronary Arteries: Comparison of Image Quality and Patient Radiation Dose. Radiology. https://doi.org/10.1148/radiol.2482072192
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.