The DOI matches its Crossref record.
Unsuspected Extracolonic Findings at Screening CT Colonography: Clinical and Economic Impact1
Abstract
PURPOSE: To evaluate the frequency and estimated costs of additional diagnostic workup for extracolonic findings detected at computed tomographic (CT) colonography in a large screening cohort. MATERIALS AND METHODS: This retrospective HIPAA-compliant study, which had institutional review board approval, evaluated extracolonic findings in 2195 consecutive asymptomatic adults (1199 women, 996 men; age range, 40-90 years; mean age, 58.0 years +/- 8.1 [standard deviation]) undergoing low-dose CT colonographic screening performed without contrast material at a single institution over a 20-month period. All diagnostic workups generated because of extracolonic findings were reviewed. Associated costs were estimated by using 2006 Medicare average reimbursement. Testing for statistical significance was performed by using the chi(2) and t tests. RESULTS: Further diagnostic workup for unsuspected extracolonic findings was performed in 133 (6.1%) of 2195 patients, including 18 patients in whom additional workup was not recommended by the radiologist. Additional testing included ultrasonography (n = 64), CT (n = 59), magnetic resonance imaging (n = 11), other diagnostic imaging tests (n = 19), nonsurgical invasive procedures (n = 19), and surgical procedures (n = 22). Benign findings were confirmed in the majority of cases, but relevant new diagnoses were made in 55 (2.5%) patients, including extracolonic malignancies in nine patients. The mean cost per patient for nonsurgical procedures was $31.02 (95% confidence interval: $23.72, $38.94); that for surgical procedures was $67.54 (95% confidence interval: $38.62, $101.55). CONCLUSION: Detection of relevant unsuspected extracolonic disease at CT colonographic screening is not rare, accounting for a relatively large percentage of cases in which additional workup was recommended. Judicious handling of potential extracolonic findings is warranted to balance the cost of additional workup against the potential for early detection of important disease, because many findings will prove to be of no clinical consequence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cunningham, D., Atkin, W., Lenz, H.-J., Lynch, H. T., Minsky, B., Nordlinger, B., & Starling, N. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60353-4 · Cited by 1,351
Lin, J. S., Bowles, E. J. A., Williams, S. B., & Morrison, C. C. (2017) · JAMA · doi:10.1001/jama.2017.0562 · Cited by 1,082
Managing Incidental Findings on Abdominal CT: White Paper of the ACR Incidental Findings Committee
Berland, L. L., Silverman, S. G., Gore, R. M., Mayo-Smith, W. W., Megibow, A. J., Yee, J., Brink, J. A., Baker, M. E., Federle, M. P., Foley, W. D., et al. (2010) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2010.06.013 · Cited by 868
Self-citationWhitlock, E. P., Lin, J. S., Liles, E., Beil, T. L., & Fu, R. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-9-200811040-00245 · Cited by 845
Lin, J. S., Perdue, L. A., Henrikson, N. B., Bean, S. I., & Blasi, P. R. (2021) · JAMA · doi:10.1001/jama.2021.4417 · Cited by 650
Metadata
- Authors
- Pickhardt, P. J., Hanson, M. E., Vanness, D. J., Lo, J. Y., Kim, D. H., Taylor, A. J., Winter, T. C., & Hinshaw, J. L.
- Venue
- Radiology
- Published
- 2008-10
- Volume
- 249
- Issue
- 1
- Pages
- 151-159
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2156553666
- Cited by
- 197
- References
- 0
- FWCI
- 9.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unsuspected Extracolonic Findings at Screening CT Colonography: Clinical and Economic Impact1. https://app.cochat.ai/papers/10.1148/radiol.2491072148
- The paper
- Pickhardt, P. J., Hanson, M. E., Vanness, D. J., Lo, J. Y., Kim, D. H., Taylor, A. J., Winter, T. C., & Hinshaw, J. L. (2008). Unsuspected Extracolonic Findings at Screening CT Colonography: Clinical and Economic Impact1. Radiology. https://doi.org/10.1148/radiol.2491072148
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.