Visualization of Cerebrospinal Fluid Movement with Spin Labeling at MR Imaging: Preliminary Results in Normal and Pathophysiologic Conditions
The DOI matches its Crossref record.
Abstract
Institutional review board approval and informed consent were obtained for this study. This study was HIPAA compliant. The purpose of this study was to visualize the movement of cerebrospinal fluid (CSF) noninvasively by using an unenhanced magnetic resonance imaging technique. A time-spatial labeling inversion pulse (SLIP) technique was applied to label, or tag, CSF in a region of interest. The tagged CSF was clearly visualized at inversion times of 1500-4500 msec after pulse labeling in both intracranial and intraspinal compartments. Noninvasive visualization of CSF movement, including bulk and turbulent flow, in normal (n = 7) and altered (n = 2) physiologic conditions was possible by using the unenhanced time-SLIP technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dreha-Kulaczewski, S., Joseph, A. A., Merboldt, K.-D., Ludwig, H.-C., Gärtner, J., & Frahm, J. (2017) · The Journal of Neuroscience · doi:10.1523/jneurosci.2754-16.2017 · Cited by 204
“In fact, the absence of any useful phase-contrast flow MRI signal in the lateral and third ventricle must be attributed to the occurrence of more complex flow in these large cavities (Yamada et al., 2008).”
BackgroundFate of nanoparticles in the central nervous system after intrathecal injection in healthy mice
Householder, K. T., Dharmaraj, S., Sandberg, D. I., Wechsler-Reya, R. J., & Sirianni, R. W. (2019) · Scientific Reports · doi:10.1038/s41598-019-49028-w · Cited by 83
Metadata
- Authors
- Yamada, S., Miyazaki, M., Kanazawa, H., Higashi, M., Morohoshi, Y., Bluml, S., & McComb, J. G.
- Venue
- Radiology
- Published
- 2008-11
- Volume
- 249
- Issue
- 2
- Pages
- 644-652
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1991417087
- Cited by
- 203
- References
- 0
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.